183
5
Electrical control
cover
5.
5.Remove the four screws (M4 × 10) that fix the
electrical control cover, and then remove the cover.
6
Removing
motor wire
5., 6.
6.Open the electrical control cover, and disconnect the
two connectors (black, white) connected to the
connectors of motor.
7
Cover
1., 2., 7.
7.Remove the two screws (M4 × 10) that fix the cover,
and then remove the cover.
8
Fan
1. to 4.,
6. to 10.
8.Release the big clamp that fixes the cords of the
supply motor and exhaust motor.
9.Remove the eight screws that fix the motor holder,
hold the holder, and then slide it to the center of the
product to remove it.
No.
Component
Procedure
Note
Screws (M4 × 10)
Push this part with
your nail to disconnect
the connector.
Screws (M4 × 10)
Exhaust motor
Supply motor
Big clamp
Clamp
Release
Screws (M4 × 6)
Machine screws
with captive washer
(M8 × 16)
Screws (M4 × 6)
Machine screws
with captive washer
(M8 × 16)
Summary of Contents for MD-VNK802HEXE