40
40
Air outlet/Air outlet flap
Exchanges the air direction according to
cooling or heating time.
Earth screw
It is prepared in the electric parts box.
Air inlet port
Sucks air inside of the room from here.
Air filter
Removes dirt or dust.
(It is included in the suction port.)
Air outlet port
Drain pan (With drain filter)
This accessory is installed at the local site.
Air filter
Removes dirt or dust.
(It is included in the suction port.)
Air inlet port
Sucks air inside of the room from here.
Earth screw
It is prepared in the electric parts box.
Earth screw
It is prepared in the electric parts box.
Front panel (Lower side)
Fixing metal holder
Vertical flap
The air can be automatically discharged
rightward/leftward at stated periods.
Horizontal flap/Air outlet port
Exchanges the air direction according
to cooling or heating time.
Air filter
Removes dirt or dust.
Air inlet port
Sucks air inside of the room from here.
Fixing metal holder (Right and left)
Drain pan
Water accumulated in the drain pan is
drained from here through the drain pipe.
[Under Ceiling Type]
[High Wall Type]
MMK-AP0071H to AP0241H
MMK-AP0072H to AP0122H
Air inlet grille
Air in the room is sucked from here.
Earth screw
Earth screws are provided in the electric
parts box.
Air filter
Removes dust and trash.
(Air filter is provided in the air inlet grille.)
Air outlet/Air outlet flap
Change the direction of the air to be
discharged according to cool/heat mode.
Button
Button to open/close the suction port
Air filter
Removes dust or trash.
(Provided on the suction port.)
Air inlet port
The air in the room is sucked in from this
port.
Earth screw
Earth screws are provided in the electric
parts box.
Air outlet/Air outlet flap
Change the direction of the air to be discharged according to cool/heat mode.
Air inlet grille
Air in the room is sucked from here.
Earth screw
Earth screws are provided in the electric
parts box.
Air outlet/Air outlet flap
Change the direction of the air to be
discharged according to cool/heat mode.
Air filter
Removes dust and trash.
(Air filter is provided in the air inlet grille.)
[Floor Standing Type]
[Floor Standing Concealed Type]
[Floor Standing Cabinet Type]
Display
section
Operation
section
ON / OFF
FAN
TEMP.
SWING/FIX
TIME
MODE
VENT
UNIT
SET
CL
FILTER
RESET TEST
TIMER SET
CODE No.
UNIT No.
TEST
SETTING
DATA
SET
R.C.
No.
H
2
15
5
7 8 9
3
1
4
6
10
11
13
16
12
14
17
CODE No.
UNIT No.
TEST
SETTING
DATA
SET
R.C.
No.
H
3-7. Parts Name of Remote Controller
Display section
In the display example, all indicators are displayed for the explanation.
In reality only, the selected contents are displayed.
• When turning on the leak breaker for the first time, [SET DATA] flashes on
the display part of the remote controller. While this display is flashing, the
model is being automatically confirmed. After the [SET DATA] display has
disappeared, you may use the remote controller.
1
SET DATA display
Displayed during the setup of the timer.
2
Operation mode select display
The selected operation mode is displayed.
3
CHECK display
Displayed while the protective device works or
a fault/error occurs.
4
Timer time display
Time on the timer is displayed.
(When a fault/error occurs, the check code is
displayed.)
5
Timer setting setup display
When pushing the Timer setting button, the
display on the timer is selected in order of
[OFF]
→
[OFF] repeat OFF timer
→
[ON]
→
No display.
6
Filter display
If “FILTER
” is displayed, clean the air filter.
7
TEST run display
Displayed during a test run.
8
Flap position display
(for 4-Way Air Discharge Cassette Type
and Under Ceiling Type model only)
Displays flap position.
9
SWING display
Displayed during the up/down movement of the
flap.
10
Set up temperature display
The selected set up temp. is displayed.
11
Remote controller sensor display
Displayed while the sensor on the remote
controller is used.
12
PRE-HEAT display
(for Heat-pump model only)
Displayed when the heating operation starts or a
defrost operation is carried out.
While this indication is displayed, the indoor fan
will stop or will go into LOW mode.
13
Operation ready display
Displayed when cooling or heating operation is
impossible because the outdoor temperature goes
out of the operable range.
14
No function display
Displayed if there is no function even when the
button is pushed.
15
Air volume select display
The selected air volume mode is displayed.
(AUTO)
(HIGH)
(MED.)
(LOW)
In the Concealed Duct High Static Pressure type
models, [HIGH] only is displayed for the air speed.
16
Mode select control display
Displayed when pushing the “Operation mode
select
” button while the operation mode is fixed
in heating or cooling mode by the system manager
of the air conditioner.
17
Central control display
Displayed when using the remote controller together
with a central control remote controller.
If the Remote controller is prohibited at the central
control side,
flashes when operating the
ON / OFF
,
MODE
,
/
buttons. The change
will not be accepted.
(The contents available to be set up on the remote
controller differ according to the central control
mode. For details, refer to Owner’s Manual of the
central control remote controller.)