background image

– 24 –

13

Specifications

* Under 70 dBA

Model

Sound pressure level (dBA)

Weight (kg)

Cooling

Heating

Declaration of Conformity

NOTE

This declaration becomes invalid if technical or operational modifications are introduced without the manufacturer’s 
consent.

Manufacturer:

Authorized 
Representative/TCF 
holder:

Nick Ball
Toshiba EMEA Engineering Director
Toshiba Carrier UK Ltd.
Porsham Close, Belliver Industrial Estate,
PLYMOUTH, Devon, PL6 7DB.
United Kingdom

Hereby declares that the machinery described below:

Generic Denomination: Air Conditioner

Model/type: 

MMD-AP0186HP-E, MMD-AP0246HP-E, MMD-AP0276HP-E 

 

MMD-AP0366HP-E, MMD-AP0486HP-E, MMD-AP0566HP-E

Commercial name:

Super Modular Multi System Air Conditioner
Super Heat Recovery Multi System Air Conditioner
Mini-Super Modular Multi System Air Conditioner (MiNi-SMMS series)

Complies with the provisions of the “Machinery” Directive (Directive 2006/42/EC) and the regulations transposing 
into national law

“Declaration of incorporation of partly completed machinery”

Must not be put into service until the final machinery into which it is to be incorporated has been declared in 
conformity with the provisions of this Directive, where appropriate.

47-EN

48-EN

TOSHIBA CARRIER (THAILAND) CO., LTD. 
144/9 Moo 5, Bangkadi Industrial Park, Tivanon road, Tambol Bangkadi,
Amphur Muang, Pathumthani 12000, Thailand

MMD-AP0186HP-E * 

34 

MMD-AP0246HP-E * 

34 

MMD-AP0276HP-E * 

34 

MMD-AP0366HP-E * 

43 

MMD-AP0486HP-E * 

43 

MMD-AP0566HP-E * 

43 

1117065599 (01)_EN.indd   25

1117065599 (01)_EN.indd   25

01/07/15   3:42 PM

01/07/15   3:42 PM

Summary of Contents for MMD-AP0186HP-E

Page 1: ...For commercial use Indoor Unit Model name Concealed Duct High Static Pressure Type MMD AP0186HP E MMD AP0246HP E MMD AP0276HP E MMD AP0366HP E MMD AP0486HP E MMD AP0566HP E 1117065599 01 _EN indd 1 1117065599 01 _EN indd 1 01 07 15 3 42 PM 01 07 15 3 42 PM ...

Page 2: ...cations pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and ...

Page 3: ...or electricians Warning indications on the air conditioner unit n o i t p i r c s e D n o i t a c i d n i g n i n r a W WARNING ELECTRICAL SHOCK HAZARD Disconnect all remote electric power supplies before servicing WARNING Moving parts Do not operate unit with grille removed Stop the unit before the servicing CAUTION High temperature parts You might get burned when removing this panel CAUTION Do n...

Page 4: ...her objects into the indoor unit while the air conditioner is running Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion Installation Suction duct length must be longer than 850 mm When the indoor unit is to be suspended the designated hanging bolts M10 or W3 8 and nuts M10 or W3 8 must be used In...

Page 5: ...wn work shut down the compressor before disconnecting the refrigerant pipe Disconnecting the refrigerant pipe with the service valve left open and the compressor still operating will cause air or other gas to be sucked in raising the pressure inside the refrigeration cycle to an abnormally high level and possibly resulting in rupture injury or other trouble CAUTION New refrigerant air conditioner ...

Page 6: ... works The quality of the items stored may be degraded Locations where high frequencies are generated by inverter equipment in house power generators medical equipment or communication equipment Malfunctioning or control trouble in the air conditioner or noise may adversely affect the equipment s operation Locations where there is anything under the unit installed that would be compromised by wetn...

Page 7: ...he indoor unit as it is packaged if possible If carrying in the indoor unit unpacked by necessity use buffering cloth or other material to not damage the unit To move the indoor unit hold the hooking brackets 4 positions only Do not apply force to the other parts such as refrigerant pipe drain pan foamed parts or resin parts Carry the package by four or more persons and do not bundle it with plast...

Page 8: ...p and down of the hanging bracket of the indoor unit to hang down the indoor unit Check that four sides are horizontal with a level gauge Horizontal degree Within 5 mm REQUIREMENT Hang the unit in a horizontal position When unit is hanged to slant it may cause overflow of drainage Install the unit within the dimension according to the figure below Use level gauge to confirm whether the unit is han...

Page 9: ...rain hose using the hose band without using adhesive Pipe material Hard vinyl chloride pipe VP25 Nominal outer diameter Ø32 mm Insulator Foamed polyethylene foam thickness 10 mm or more 1 5 m to 2 m Support bracket Downward slope 1 100 or more Arched shape Trap Downward slope 1 100 or more Collective piping As long as possible Approx 10 cm Heat insulator Incorrect VP30 Flexible drain hose Hose ban...

Page 10: ...g from the drain pipe connecting port and check that no water is leaking from the drain pipe After checking that the water drains and there are no water leaks turn off the power connect the float switch connector to its original location CN34 on the printed circuit board and return the electrical control box to its original position Supply water hose Pull out connector CN34 Red from P C board Whit...

Page 11: ... pressure loss option 0 25 50 75 100 125 150 175 200 225 250 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Static Pressure Pa 200Pa 150Pa 100Pa 50Pa Spigot Flange pressure loss option Filter set pressure loss option Fan characteristics Air Flow m3 h Standard Air Flow 800m3 h AP0186 type AP0246 0276 type AP0366 type Standard Air Flow 1 200m3 h Air Flow m3 h Air Flow m3 h Standard Air Flow ...

Page 12: ...Canvas joint Air conditioner Air supply port Silencer chamber Air filter Air inlet Check port Silencer chamber 180 Outside 1340 Outside 87 13 22 22 87 180 Outside 940 Outside 20 100 100 100 100 100 100 100 100 100 13 Arrangement Referring to the following dimensions manufacture duct at the local site Air inlet Air inlet 975 7 100 100 100 100 100 100 100 100 100 418 180 276 256 50 100 100 100 100 1...

Page 13: ...ipe connections Pressure of R410A is higher than that of R22 Approx 1 6 times Therefore using a torque wrench tighten the flare pipe connecting sections which connect the indoor and outdoor units of the specified tightening torque Incorrect connections may cause not only a gas leak but also a trouble of the refrigeration cycle CAUTION Tightening with an excessive torque may crack the nut depending...

Page 14: ...e product Do not damage or scratch the conductive core and inner insulator of power and system interconnection wires when peeling them Use the power cord and system interconnection wire of specified thickness type and protective devices required Do not connect 220 V 240 V power to the terminal blocks for control wiring Otherwise the system will fail REQUIREMENT For power supply wiring strictly con...

Page 15: ...controller inter unit wiring Wire size 0 5 mm to 2 0 mm Total wire length of remote controller wiring and remote controller inter unit wiring L L1 L2 Ln In case of wired type only Up to 500 m In case of wireless type included Up to 400 m m 0 0 2 o t p U n L 2 L 1 L g n i r i w t i n u r e t n i r e l l o r t n o c e t o m e r f o h t g n e l e r i w l a t o T L1 L n L 2 L Indoor unit Remote contro...

Page 16: ... used for the first time it will take some moments after the power has been turned on before the remote controller becomes available for operations This is normal and is not indicative of trouble Concerning the automatic addresses The automatic addresses are set up by performing operations on the outdoor interface circuit board While the automatic addresses are being set up no remote controller op...

Page 17: ...connected To set up a tap change follow to the basic operation procedure 1 2 3 4 5 6 Specify 5d to the CODE No in procedure 3 For the SET DATA of procedure 4 select a SET DATA of the external static pressure to be set up from the following table The list above is when SW501 1 and SW501 2 is OFF If the setting is wrong P12 may appear indicating a fan motor error SET DATA External static pressure 00...

Page 18: ...1 1 C 0002 2 C Factory default 0003 3 C 0004 4 C 0005 5 C 0006 6 C SET DATA 0000 0001 Remotecontroller sensor Not used Factory default Used 10Test run Before test run Before turning on the power supply carry out the following procedure 1 By using 500 V megger check that resistance of 1 MΩ or more exists between the terminal block L to N and the earth grounding If resistance of less than 1 MΩ is de...

Page 19: ...r cover the air discharge In addition stop the operation before replacing the opening the service panel After the test run reset the circuit breaker of the indoor unit TEMPORARY button 11Maintenance 1 Take out the air filter sold separately 2 Cleaning with water or vacuum cleaner If dirt is heavy clean the air filter by tepid water with neutral detergent or water After cleaning with water dry the ...

Page 20: ...t r i d t s u D r o o d n I r sold separately e t l i F Wash the filter with water when it is contaminated Replace it when it is damaged r o o d n I n a F Vibration balance Dust dirt appearance Replace the fan when vibration or balance is terrible Brush or wash the fan when it is contaminated Air intake discharge grilles Indoor outdoor Dust dirt scratches Fix or replace them when they are deformed...

Page 21: ... r o o d n I s e s s e r d d a t i n u r o o d n i d e t a c i l p u D s e s s e r d d a t i n u r o o d n i d e t a c i l p u D 8 0 E 8 0 E r e l l o r t n o c e t o m e R s r e l l o r t n o c e t o m e r r e t s a m d e t a c i l p u D 9 0 E t i n u r o o d n I C M t i n u r o o d n i n e e w t e b r o r r e n o i t a c i n u m m o C 0 1 E E12 E12 01 Indoor Outdoor units communication 02 Outdoo...

Page 22: ...H03 01 Comp 1 side 02 Comp 2 side 03 Comp 3 side U D P I r o r r e m e t s y s t i u c r i c t c e t e d t n e r r u C F I n o i t a r e p o o m r e h t e s a c 1 p m o C 4 0 H 4 0 H F I g n i r i w s i m r o s n e s 1 D T 5 0 H 5 0 H F I n o i t a r e p o e v i t c e t o r p e r u s s e r p w o L 6 0 H 6 0 H F I n o i t c e t o r p e v i t c e t e d n w o d l e v e l l i O 7 0 H 7 0 H H08 H08 01 ...

Page 23: ...00 01 Comp 1 side 02 Comp 2 side 03 Comp 3 side T L A Phase missing detection Power failure detection Inverter DC voltage error comp Inverter DC voltage error comp Inverter DC voltage error comp I F P07 P07 01 Comp 1 side 02 Comp 2 side 03 Comp 3 side F I U D P I r o r r e t a e h r e v o k n i s t a e H T L A a e h o N T L A s s e r d d a e g a r o t s t a e h d e t c e t e D 9 0 P 9 0 P t i n u ...

Page 24: ...vice indication Outdoor unit 7 segment display Sensor block display of receiving unit h s a l F y d a e R r e m i T n o i t a r e p O e d o c y r a i l i x u A K N I L C C T e c i v e d l o r t n o c l a r t n e c K N I L C C T n i r o r r e g n i d n e S 5 0 C K N I L C C T e c i v e d l o r t n o c l a r t n e c K N I L C C T n i r o r r e g n i v i e c e R 6 0 C e c a f r e t n i l o r t n o c ...

Page 25: ...dular Multi System Air Conditioner Super Heat Recovery Multi System Air Conditioner Mini Super Modular Multi System Air Conditioner MiNi SMMS series Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulations transposing into national law Declaration of incorporation of partly completed machinery Must not be put into service until the final machinery into which...

Page 26: ...or more refrigerating systems in a single refrigerating device the amounts of refrigerant should be as charged in each independent device For the amount of charge in this example The possible amount of leaked refrigerant gas in rooms A B and C is 10 kg The possible amount of leaked refrigerant gas in rooms D E and F is 15 kg NOTE 2 The standards for minimum room volume are as follows 1 No partitio...

Page 27: ... F STATIC 5 0005 F STATIC 6 0006 External static pressure CODE NO 5d F NO CHANGE F STANDARD 0000 F STATIC 1 0001 F STATIC 2 0002 F STATIC 3 0003 F STATIC 4 0004 F STATIC 5 0005 F STATIC 6 0006 Have you changed lighting time of filter sign If not fill check mark in NO CHANGE and fill check mark in ITEM if changed respectively For check method refer to APPLICABLE CONTROLS in this manual Filter sign ...

Page 28: ...THAILAND CO LTD 144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND 1117065599 1117065599 01 _EN indd 28 1117065599 01 _EN indd 28 01 07 15 3 42 PM 01 07 15 3 42 PM ...

Reviews: