No.
⑫
Part name
Procedure
Remarks
Sensor TA
Reactor
NOTE
After assembling, check if that there is no abnormal sound,
vibration, or puncture.
Check the exchange point when you have a problem.
Electrical parts
box
TA sensor holder
TA sensor
CN104
1)
1.
Detachment
1)
Perform 1 of
①
and 1 of
7
.
2)
Remove the connector of the wires of TA sensor from
the control P.C. board.
3)
Pinch the lock of the TA sensor holder from the outside
of the electrical parts box and push it into the inside
of
the electrical parts box.
2.
Attachment
Attach the TA sensor to the original position.
2) Attach
the wires of TA sensor in the holder as
before.
3)
Attach the electr
i
cal parts box as before.
screws
Reactor
Reactor cover
CN511
CN510
Reactor assembly
13
1.
Detachment
1)
Perform 1 of
①
and 1 of
7 .
2)
Remove the connector of the wires of the reactor
from the fan control P.C. board.
3)
Remove the screws fixing the reactor cover.
Slide
the reactor cover to the arrow direction and
remove.
4)
Remove the screws fixing the reactor.
5)
Remove
the reactor from the reactor cover.
2.
Attachment
1)
Attach the reactor to the reactor cover.
2)
Attach the reactor cover as before.
3)
Attach
the wires of the reactor in the holder as
before.
- 9
1
-
S
crew