SMMS High-Wall Type
Installation Manual
– 14 –
EN
5.
Cutting a Hole and Mounting Installation Plate
Cutting a hole
In case of installing the refrigerant pipes from the
rear:
1
Decide the hole position for piping at 100
mm from the arrow mark (
) on the
installation plate and drill a hole with Ø65
mm at a slight downward slant toward
outdoor side.
23 mm
The centre of the pipe hole is
above the arrow
100 mm
Pipe hole
NOTE
• To drill a wall that contains a metal lath, wire lath
or metal plate, use a pipe hole brim ring sold
separately.
Mounting the installation plate
For installation of the indoor unit, use the paper
pattern in the accessory parts.
107
85
127.5
170
Hook
Hook
Pipe hole
Indoor unit
Thread
Weight
Mounting Screw
Installation
plate
Pipe hole
Hook
Fix the installation plate to the wall with screws to
make the indoor unit fit to the wall.
When the installation plate is
directly mounted on the wall
1
Securely fit the installation plate onto the
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2
To mount the installation plate on a
concrete wall with anchor bolts, utilize the
anchor bolt holes as illustrated in the above
figure.
3
Install the installation plate horizontally in
the wall.
CAUTION
To install the installation plate with a mounting
screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in
personal injury and property damage.
Projection
15 mm or less
Clip anchor
(local parts)
Mounting screw
4 × 25
Anchor bolt
5 mm dia. hole
OK
NO
GOOD
NO
GOOD
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit
falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting
screws.
NOTE
• Secure four corners and lower parts of the
installation plate with 6 mounting screws to
install it.
14-EN
High-Wall Type