background image

1111058001

Information according to EMC Directive 2004/108/EC

(Name of the manufacturer)

TOSHIBA CARRIER CORPORATION

(Address, city, country)

336 Tadehara, Fuji-shi, Shizuoka-ken

416-8521 Japan

(Name of the Importer / Distributor in EU)

Toshiba Carrier UK Ltd.

(Address, city, country)

Porsham Close, Belliver Industrial Estate, PLYMOUTH,

Devon, PL6 7DB. United Kingdom

Summary of Contents for MMK-AP0074MH-E

Page 1: ...English Owner s Manual AIR CONDITIONER MULTI TYPE Indoor Unit Model name High Wall Type MMK AP0074MH E MMK AP0094MH E MMK AP0124MH E Owner s Manual 001111056701_01EN book Page 1 Thursday December 8 2011 6 03 PM ...

Page 2: ...ns 33 Thank you very much for purchasing TOSHIBA Air Conditioner Please read this owner s manual carefully before using your Air Conditioner Be sure to obtain the Owner s manual and Installation manual from constructor or dealer Request to constructor or dealer Please clearly explain the contents of the Owner s manual and hand over it ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type ...

Page 3: ...quainted with the knowledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating to working at heights with the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge re...

Page 4: ...es before the operation otherwise there might be the burst CAUTION Do not climb onto the fan guard Doing so may result in injury WARNING ELECTRICAL SHOCK HAZARD Disconnect all remote electric power supplies before servicing WARNING Moving parts Do not operate unit with grille removed Stop the unit before the servicing CAUTION High temperature parts You might get burned when removing this panel CAU...

Page 5: ...t broken contact your dealer Installation Only a qualified installer 1 or qualified service person 1 is allowed to carry out the electrical work of the air conditioner Under no circumstances must this work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the in...

Page 6: ...t for you Do not touch the aluminum fin of the outdoor unit You may injure yourself if you do so If the fin must be touched do not touch it yourself but contact a qualified installer or a qualified service person Do not climb onto or place objects on top of the outdoor unit You may fall or the objects may fall off of the outdoor unit and result in injury Do not place any combustion appliance in a ...

Page 7: ...t the circuit breaker to the ON position until the repairs are completed If there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the OFF position and contact a qualified installer or a qualified service person to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted If there is a danger of the outd...

Page 8: ...tions Otherwise it may cause a malfunction or water leak from the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result ...

Page 9: ...g height 12 cartons can be stacked in this case Do not walk on this carton This side up Do not step Handle with care Other cautions Description CAUTION Injury possibility Don t handle with packing band or may get injured in case of broken band Stacking notice In case that cardboard boxes protrude out of pallet when stacking lay a 10 mm thick plywood over the pallet 11 cartons 8 EN 001111056701_01E...

Page 10: ...irflow louver 7 Vertical airflow louver 8 Display panel 9 Infrared signal receiver 10 Remote controller wireless 11 Remote controller wired sold separately Remote controller Remote controller holder Batteries two R03 AAA SET TIME TIMER SET TEST FILTER RESET CL FAN SAVE SWING FIX VENT MODE UNIT LOUVER 2 1 3 6 5 9 7 4 8 11 10 9 EN 001111056701_01EN book Page 9 Thursday December 8 2011 6 03 PM ...

Page 11: ...very Multi with no auto changeover control setting or if you select HEAT in a Cooling Only model an alarm sound pi pi from the air conditioner due to disagreement in operation mode Change the operation mode with the MODE button on the wireless remote controller This disagreement indication cannot be deleted by the wired remote controller When local prohibition is set by the central control from ot...

Page 12: ...ON Push this button to set the ON timer 10 Reserve button SET Push this button to reserve time settings A receiving beep is heard 11 Cancel button CLR Push this button to cancel ON timer and OFF timer A receiving beep is heard 12 High power button Hi POWER This function is not operated group control Push this button to start the high power operation 13 Memory button MEMO Push this button to stand ...

Page 13: ...levels LOW LOW MED MED HIGH can be indicated Indicates when the operation mode is Dry 5 TIMER and clock time display The time set for timer operation or clock time is indicated The present time is always indicated except for TIMER operation 6 Hi POWER display Indicates when the Hi POWER operation starts Push the Hi POWER button to start and push it again to stop the operation 7 MEMORY display Flas...

Page 14: ...n Batteries To replace the batteries use two new batteries R03 AAA In normal use the batteries will last about one year Replace the batteries if there is no receiving beep from the indoor unit or when the air conditioner cannot be operated using the remote controller To avoid malfunctions by battery leakage remove the batteries when the remote controller will not be used for more than one month 1 ...

Page 15: ...n minute steps 2 SET button Push the SET button The current time is indicated and the clock starts Clock adjusting 1 CLOCK button Push the CLOCK button The CLOCK display flashes 2 TIMER button Push the TIMER button to set the current time Each push of the TIMER button changes the time by one minute Pushing the TIMER button continually changes the time by ten minutes 3 SET button Push the SET butto...

Page 16: ...button 2 Units other than the Header unit cannot be operated with remote control and the TEMPORARY button When the air conditioner is operated with wireless remote control transmission should be sent to the Header unit Header and follower indoor units are decided through address setting upon installation Follower unit will not receive any signals from remote control Air conditioner will not work e...

Page 17: ...oller move these appliances or consult your local dealer Location of the remote controller Keep the remote controller where its signals can reach the receiver of the indoor unit a distance of 7 m is allowed When the timer operation is selected the remote controller automatically transmits a signal to the indoor unit at the specified time If you keep the remote controller in a position that hinders...

Page 18: ... Stop START STOP button Push this button again to stop the air conditioner NOTE When the indoor unit is operated together with a cooling only outdoor unit Heat appears on the remote controller but the heating operation is disabled Dry operation Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select DRY 3 Temperature button Set the desired temperatu...

Page 19: ...STOP button Push this button again to stop the air conditioner Automatic operation auto changeover Start 1 START STOP button Push this button to start the air conditioner 2 Mode select button MODE Select A 3 Temperature button Set the desired temperature The lamp green on the display panel of the indoor unit lights The operation mode is selected in accordance with the room temperature and operatio...

Page 20: ...to set the timer The timer time is indicated and the timer starts Cancelling TIMER 4 CLR button Push the CLR button to cancel the timer setting CAUTION When the timer operation is selected the remote controller automatically transmits the timer signal to the indoor unit at the specified time Therefore keep the remote controller in a location where it can transmit the signal to the indoor unit prop...

Page 21: ... button ON timer OFF timer Stop Operation Stop You can use this setting to start the air conditioner when you wake up and stop it when you leave the house Example To start the air conditioner next morning and stop it Setting combined TIMER 1 Push the ON button 2 Push the TIMER button to adjust the ON timer 3 Push the OFF button 4 Push the TIMER button to adjust the OFF timer 5 Push the SET button ...

Page 22: ... power operation mode automatically controls room temperature airflow and operation mode so that the room is quickly cooled in summer and warmed in winter Setting Hi POWER mode 1 Hi POWER button Push the Hi POWER button after starting any operation At the same time the Hi POWER mark on the remote controller is indicated Cancelling Hi POWER mode 1 Hi POWER button Push the Hi POWER button once again...

Page 23: ...3 seconds or if another button is pushed the MEMORY setting is cancelled Operation modes which can be memorized with the MEMO button are MODE Temperature FAN TIMER and Hi POWER To operate the air conditioner with the setting memorized by the MEMO button 1 PRESET button Push the PRESET button The setting memorized with the MEMO button will be indicated and the air conditioner operates with regards ...

Page 24: ...tton on the remote controller to move the louver in the desired direction In subsequent operations the vertical airflow is automatically set in the direction to which you adjusted the louver using the FIX button NOTE Operating angle of vertical airflow louver will be different during cooling dry and heating operation To automatically swing the airflow direction Perform this function when the air c...

Page 25: ... button If you move the louver manually it may malfunction during operation If the louver malfunctions stop the air conditioner once and restart When the air conditioner is started immediately after it was stopped the vertical airflow louver might not move for 10 seconds or so Louver operation is limited when group control is used Refer to 6 Limited operation by group control Adjust the horizontal...

Page 26: ...d windows more often than necessary Window curtains In cooling close the curtains to avoid direct sunlight In heating close the curtains to keep the heat in Use the timer effectively Set the timer for the desired operating time Get uniform circulation of room air Adjust airflow direction for even circulation of room air TIMER Gee chilly Control Clean please Use the timer effectively Blows upward C...

Page 27: ...roller is not used models with the auto changeover cooling heating function perform A operation and those without the function perform cooling operation set temperature 24 C fan HIGH CAUTION Continuous pushing of the TEMPORARY button for 10 seconds and above will start the forced cooling operation This will impose burden on the air conditioner Do not perform this for the purposes other than test r...

Page 28: ... used Cooling operation In the operation suppression zone where capacity is kept to the minimum over cooling is prevented by raising the temperature setting by 1 C after 1 hour and by 2 C after 2 hours of operation The room temperature is thus regulated between the operation suppression zone and the set temperature Heating operation In the operation suppression zone where capacity is kept to the m...

Page 29: ...may damage or fade the surface of the unit Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform If you will not use the unit for at least 1 month 1 Operate the air conditioner in FAN ONLY mode for about half a day to dry the inside of the unit 2 Stop the air conditioner and turn off the main power switch 3 Remove the ba...

Page 30: ...n 2 Take hold of the left and right handles of the air filter and lift it up slightly then pull it downward to take it out from the filter holder 3 Use a vacuum cleaner to remove the dust from the filters or wash them with water If you wash the air filters dry them in the shade 4 Insert the upper portion of air filter confirming to fit its right and left edges on the indoor unit until it is firmly...

Page 31: ...oating to peel off If very dirty clean the air intake grille with a neutral detergent for kitchen use and rinse it off with water 3 Wipe out water from the air intake grille and dry it 4 Fit the left and right arms of the air intake grille to the shafts on the two sides of the air conditioner and push in completely and then push in the centre arm 5 Check that the centre arm has been completely ins...

Page 32: ...ut Stoppage of electric current The batteries in the remote controller are exhausted ON TIMER is set Signal is sent to the follower indoor unit with the remote controller see page 16 Operation of the indoor unit is limited by the wired remote controller that is controlling some other system When signal is transmitted warning sound 5 beeps will be heard Disagreement in operation mode occurred When ...

Page 33: ...on of parts or change of refrigerant flow The room air is smelly A bad odour comes from the air conditioner Smells impregnated in the wall carpet furniture clothing or furs are coming out Louver does not work in the FIX or SWING mode The FIX and SWING modes are restricted under the group control see page 15 Fan and louvers of the indoor unit moves when the unit is not operated When the other indoo...

Page 34: ...ual 33 Toshiba 14 Specifications Under 70 dBA Model Sound power level dBA Weight kg Main unit Cooling Heating MMK AP0074MH E 11 MMK AP0094MH E 11 MMK AP0124MH E 11 33 EN 001111056701_01EN book Page 33 Thursday December 8 2011 6 03 PM ...

Page 35: ...e PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMK AP0074MH E MMK AP0094MH E MMK AP0124MH E Commercial name Super Modular Multi System Air Conditioner Super Heat Recovery Multi System Air Conditioner Mini Super Modular Multi System Air Conditioner MiNi SMMS series Complies with the provisions of the Machine...

Page 36: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...