21
‒
21-EN
Installation Manual
7
INDOOR UNIT FIXING
8
DRAINAGE
1. Pass the pipe through the hole in the wall, and
hook the indoor unit on the installation plate at
the upper hooks.
2. Swing the indoor unit to right and left to con
fi
rm
that it is
fi
rmly hooked up on the installation
plate.
3. While pressing the indoor unit onto the wall,
hook it at the lower part on the installation
plate. Pull the indoor unit toward you to con
fi
rm
that it is
fi
rmly hooked up on the installation
plate.
1
2
Installation
plate
Hook here.
Hook
• For detaching the indoor unit from the
installation plate, pull the indoor unit toward
you while pushing its bottom up at the speci
fi
ed
parts.
Push
Push
REQUIREMENT
The lower part of indoor unit may float, due
to the condition of piping and you cannot fix
it to the installation plate. In that case, use
the screws provided to fix the unit and the
installation plate.
Especially when the pipes are pulled out
from the left side, the unit must be screwed
to the installation plate.
Lid screws
Screws
1. Run the drain hose sloped downwards.
NOTE
• Hole should be made at a slight downward
slant on the outdoor side.
2. Put water in the drain pan and make sure that
the water is drained out of doors.
3. When connecting extension drain hose,
insulate the connecting part of extension drain
hose with shield pipe.
50 mm
or more
Do not rise the drain hose.
Do not form the drain hose
into a wavy shape.
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage
ditch.
Drain hose
Extension drain hose
Inside the
room
Shield pipe
CAUTION
Arrange the drain pipe for proper drainage from
the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed to
drain water collected from dew, which forms on
the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
Wall
Space for pipes
Drain guide