5
CUTTING A HOLE AND MOUNTING INSTALLATION
PLATE
Cutting a hole
In case of installing the refrigerant pipes from the
rear:
1
Decide the hole position for piping at
110 mm from the arrow mark (
Ö
) on the
installation plate and drill a hole at a slight
downward slant toward outdoor side.
Dia 80 mm
Unit outline
110 mm
50
NOTE
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe
hole brim ring sold separately.
Mounting the installation plate
Mounting
screw
Pipe
hole
Indoor unit
Hook
Hook
Thread
Weight
Pipe hole
Hook
Installation
plate
Mounting screw
Anchor bolt
holes
170
123
110
50
57
85
Mounting screw
Mounting
screw
61
23
Hook
When the installation plate is
directly mounted on the wall
1. Securely
fi
t the installation plate onto the
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2. To mount the installation plate on a
concrete wall with anchor bolts, utilize
the anchor bolt holes as illustrated in the
above
fi
gure.
3. Install the installation plate horizontally in
the wall.
CAUTION
When installing the installation plate with a
mounting screw, do not use the anchor bolt
hole. Otherwise the unit may fall down and
result in personal injury and property damage.
5 mm dia. hole
Clip anchor
(local parts)
Mounting screw
Ø4 mm × 25
R
Anchor bolt
Projection
15 mm or less
NO
GOOD
NO
GOOD
OK
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit
falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting
screws.
NOTE
• Secure four corners and lower parts of the
installation plate with 6 mounting screws to
install it.