6
3
Check code display list (Outdoor unit)
[SMMS-i interface detects error: Main example]
(
∗
)
¡
: Goes on,
¥
: Flashes,
l
: Goes off
A (Alternate)
: Flashing condition is alternate when there are two flashing LED.
S (Simultaneously) : Two LED flash simultaneously when there are two flashing LED.
Check code display
TCC-LINK central &
remote controllers
E06
(E04)
(E08)
E12
E15
E16
E19
E20
E21
E22
E23
E25
E26
E28
E31
F04
F05
F06
F07
F08
F11
F12
F15
F16
F22
F23
F24
F31
Sensor lamp display
Block display
Operation Timer Ready Flash
l
l
¥
l
l
¥
¥
l
l
¥
l
l
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
l
l
¥
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
—
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
A
¥
¥
¡
S
Outdoor 7-segment
Auxiliary code
E06
No. of indoor units which received signal
normally
E07
—
E08
Duplicated indoor unit number
E12
01: Indoor/Outdoor communication
02: Communication between Outdoor units
E15
—
E16
00: Capacity over
01 ~ : No. of connected units
E19
00: No center outdoor unit
02: 2 or more center outdoor units
E20
01: Connected to outdoor of other line
02: Connected to indoor of other line
E21
00: Duplicated header units
02: No header unit
E22
—
E23
—
E25
—
E26
Receive error of outdoor address
E28
Detected outdoor unit number
E31
F04
—
F05
—
F06
01: TE1
02: TE2
F07
—
F08
—
F11
—
F12
—
F15
—
F16
—
F22
—
F23
—
F24
—
F31
—
Main defective position
Decrease of quantity of indoor units
Indoor/Outdoor communication circuit error
Duplicated indoor address
Automatic address start error
There is none during auto addressing.
No. of connected indoor units:
Over capacity
No. of center outdoor units error
Connected to other line during automatic
addressing
Header heat unit quantity error
Decrease of heat unit quantity
Send error communication between
outdoor units
Duplicated terminal outdoor address setting
Decrease of connected outdoor units
Terminal outdoor error
IPDU communication error
Outdoor discharge temp. sensor (TD1) error
Outdoor discharge temp. sensor (TD2) error
Outdoor heat exchanger temp. sensor
(TE1, TE2) error
Outdoor liquid temp. sensor (TL) error
Outdoor outer air temp. sensor (TO) error
—
Outdoor suction temp. sensor (TS1) error
Outdoor temp. sensor (TE1, TL) miswiring
Outdoor pressure sensor (Pd, Ps) miswiring
Outdoor discharge temp. sensor (TD3) error
Low pressure (Ps) sensor error
High pressure (Pd) sensor error
Outdoor EEPROM error
Description
No communication from indoor unit
(Decrease of connected indoor units)
Signal cannot be sent to indoor unit.
(
→
There is no communication from outdoor unit.)
There are multiple indoor units having the same address.
(Detected also at indoor unit side)
Automatic indoor address operation while setting automatic address of other system
Outdoor automatic address operation while setting automatic indoor address
There is no signal receiving from outdoor unit during automatic addressing.
Total capacity of indoor units exceeded (total capacity of outdoor units × 135%)
There is no center outdoor unit or there are 2 or more outdoor units in 1 line.
Indoor unit of other line was detected during automatic address is been setting.
There is no header heat unit in the system, or there are multiple header units.
No communication from heat unit (Decrease of connected heat units)
Sending to other outdoor is unavailable.
Manually set outdoor address was duplicated.
No communication from terminal outdoor unit
(Decrease of connected terminal outdoor units)
Center outdoor unit detected terminal outdoor unit error.
(For terminal outdoor unit, details are displayed.)
No communication of each IPDU (P.C. board) in inverter box
Open/Short of outdoor discharge temp. sensor (TD1) was detected.
Open/Short of outdoor discharge temp. sensor (TD2) was detected.
Open/Short of heat exchanger temp. sensor (TE1, TE2) was detected.
Open/Short of outdoor liquid temp. sensor (TL) was detected.
Open/Short of outer air temp. sensor (TO) was detected.
—
Open/Short of outdoor suction temp. sensor (TS1) was detected.
Miswiring by temp. sensor (TE1, TL) was detected.
Miswiring by outdoor pressure sensor (Pd, Ps) was detected.
Open/Short of outdoor discharge temp. sensor (TD3) was detected.
Output voltage of low pressure (Ps) sensor detected 0.
Output voltage of high pressure (Pd) sensor detected 0 or error value was
detected during stop of compressor.
Outdoor EEPROM error
(Center unit stops alarm and terminal unit continues operation.).
A3-IPDU
FAN
A3-IPDU
FAN
1
2
3 IPDU
1
2
3 IPDU
01
¡
0A
¡
¡
02
¡
0B
¡ ¡
¡
03
¡ ¡
0C
¡ ¡
04
¡
0D
¡
¡ ¡
05
¡
¡
0E
¡ ¡ ¡
06
¡ ¡
0F
¡ ¡ ¡ ¡
07
¡ ¡ ¡
08
¡
¡
mark:
09
¡
¡
Error position.