– 58 –
FILE NO. SVM-
16041
Bloc
k displa
y (
∗
)
Oper
ation
Timer
Ready
Flash
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
��
�
A
��
�
A
��
�
A
��
�
A
��
�
S
�
�
�
S
�
�
�
S
�
�
�
S
�
�
�
S
�
�
�
S
�
�
�
S
�
�
�
A
�
�
�
A
�
�
�
A
�
�
�
A
On the remote controller (W
ire
d r
emote controller
, Centr
al control remote controller) and on the interf
ace P
.C
. board of the outdoor
unit, LCD displa
y par
t (Remote controller) or
When a troub
le occur
red, the method to judge the troub
le or def
ectiv
e position of the air cond
itioner b
y this self-diagnosis fu
nction is sho
wn belo
w
.
The f
ollo
wing tab
le sho
ws the list of each chec
k code that each de
vice detects
. Chec
k the chec
k contents in the f
ollo
wing tab
le
according to position to be chec
ked.
•
Chec
k from the indoor remote controller or
TCC-LINK centr
al controller
: Ref
er to
“Displa
y on remote controller &
TCC-LIN
K centr
al controller”
in the f
ollo
wing tab
le
.
•
Chec
k from outdo
or
u
nit:
Ref
er to
“Displa
y of outdoor se
gment
” in the f
ollo
wing tab
le
.
•
Chec
k from indoor unit of wireless remote controller
: Ref
er to R
ec
ei
ve
r
la
m
p displa
y”
in the f
ollo
wing tab
le
.
Chec
k code displa
y list (Indoor unit)
[I
n
d
o
o
r
u
n
it
d
et
ec
ts
e
rr
o
r.]
(
∗
)
�
: Goes on,
�
: Flashes
,
�
: Goes off
A (Alter
nate)
: Flashing condition is alter
nate when there are tw
o flashing LED
.
S (Sim
ultaneously)
: T
w
o LED flash sim
ultaneously when there are tw
o flashing LED
.
Chec
k code displa
y
TCC-LINK central & remote contr
oller
E03
E04
E08
E10
E18
F01
F02
F03
F10
F29
L03
L07
L08
L09
L20
L30
P01
P10
P12
P31
Outdoor 7-segment
A
uxiliar
y code
—
—
—
—
E
08
D
up
lic
at
ed
in
do
or
u
ni
t N
o.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
L08
—
—
—
—
—
L3
0
D
et
ec
te
d
in
do
or
u
ni
t N
o.
—
—
P10
D
et
ec
te
d
in
do
or
u
ni
t N
o.
—
—
—
—
Main def
ective position
Regular comm
unication error betw
een indoor
and remote controller
Regular comm
unication error betw
een indoor
and outdoor
Duplicated indoor address
Comm
unication error betw
een indoor MCU
Regular comm
unication error betw
een header
an
d
fo
llo
w
er
in
in
do
or
un
it
Indoor heat e
xchanger temp
. sensor (TCJ) error
Indoor heat e
xchanger temp
. sensor (TC2) error
Indoor heat e
xchanger temp
. sensor (TC1) error
Room tem.
Sensor (T
A) error
Indoor or other P
.C
. board error
Duplicated setting of header in indoor g
roup
There is g
roup cab
le in individual indoor unit.
Indoor g
roup address is unset.
In
do
or
c
ap
ac
ity
is
u
ns
et
.
Duplicated centr
al control system address
Exter
nal error w
as input in indoor (Interloc
k).
Indoor A
C
fan error
In
do
or
o
ve
rf
lo
w
w
as
d
et
ec
te
d.
Indoor DC f
an error
Other indoor unit error
Description
N
o
co
m
m
un
ic
at
io
n
fr
om
r
em
ot
e
co
nt
ro
lle
r
an
d n
et
w
or
k
ad
apt
er
(No centr
al control system comm
unication also)
No comm
unication from outdoor unit
A
n
ad
dr
es
s
sam
e
to
s
el
f a
dd
re
ss
w
as
d
et
ect
ed
.
Comm
unication error betw
een MCU of main motor microprocessors
Regular comm
unication betw
een header and f
ollo
w
er units in indoor unit
w
as impossib
le
.
Open/shor
t of heat e
xchanger temp
. sensor (TCJ) w
as detected.
Open/shor
t of heat e
xchanger temp
. sensor (TC2) w
as detected.
Open/shor
t of heat e
xchanger temp
. sensor (TC1) w
as detected.
Open/shor
t of room temp
. sensor (T
A) w
as detected.
Indoor EEPR
OM error (Other error ma
y be detected.)
There w
ere m
ultiple header units in a g
roup
.
There is e
ven an indoor unit connected to g
roup in individual indoor unit.
Indoor g
roup address is unset.
(Detected also at outdoor unit side)
Capacity of indoor unit is unset.
Setting of centr
al control system address is duplicated.
System abnor
mally stopped b
y input of e
xter
nal error (CN80).
Error of indoor A
C
can w
as detected.
(F
an motor ther
mal rela
y oper
ation)
Float s
witch oper
ated.
Error (Ov
er-current, loc
k, etc.) of indoor DC f
an w
as detected.
Group f
ollo
wer unit cannot be oper
ated b
y [E03/L03/L07/L08] alar
m of
header unit.
Note)
The chec
k code displa
y ma
y be diff
erent according to the detected de
vice e
ven same error contents such as comm
unication error
.
7-
se
gm
en
t displa
y par
t (on outdoor interf
ace P
.C
. board) is pro
vided in order to displa
y the oper
ation status
.
R
ec
ei
ve
r lamp displa
y
8-2. How to check