background image

– 3 –

• Never insert your finger or a stick into the air intake or discharge.

Doing so may result injury as the fan is rotating at high speed inside the unit. 

• Consult the shop where you purchased the air conditioner if air conditioning (cooling and heating) is not performed properly 

as a refrigerant leakage may be the cause. Confirm the repair details with a qualified service person(*1) when the repair 
includes additional charging of the refrigerant. 

• Be sure to stop running the air conditioner and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

Repairs

• When you have noticed that some kind of error (such as when an error display has appeared, there is a smell of burning, 

abnormal sounds are heard, the air conditioner fails to cool or heat or water is leaking) has occurred in the air conditioner, 
do not touch the air conditioner yourself but set the circuit breaker to the OFF position, and contact a qualified service 
person. Take steps to ensure that the power will not be turned on (by marking “out of service” near the circuit breaker, for 
instance) until qualified service person arrives. Continuing to use the air conditioner in the error status may cause 
mechanical problems to escalate or result in electric shocks, etc.

• If you have discovered that the fan grille is damaged, do not approach the outdoor unit but set the circuit breaker to the OFF 

position, and contact a qualified service person to have the repairs done. Do not set the circuit breaker to the ON position 
until the repairs are completed.

• If you have discovered that there is a danger of the indoor unit’s falling, do not approach the indoor unit but set the circuit 

breaker to the OFF position, and contact a qualified installer or a qualified service person to refit the unit. Do not set the 
circuit breaker to the ON position until the unit has been refitted.

• If you have discovered that there is a danger of the outdoor unit’s toppling over, do not approach the outdoor unit but set 

the circuit breaker to the OFF position, and contact a qualified installer or a qualified service person to have the 
improvements or refitting done. Do not set the circuit breaker to the ON position until the improvements or refitting is 
completed.

• Do not customize the unit. Doing so may result in fire, electric shock, etc.

Relocation

• When the air conditioner is to be relocated, do not relocate it yourself but contact a qualified installer or a qualified service 

person. Failure to relocate the air conditioner properly may result in electric shocks and/or a fire.

CAUTION

To disconnect the appliance form the main supply

• This appliance must be connected to the mains by means of a switch with a contact separation of at least 

3 mm

.

Installation fuse (all types can be used) must be used for the power supply line of this air conditioner.

Installation

• Certainly lay the drain hose for perfect draining. Bad drainage may cause flooding in the house and getting furniture wet.
• Make sure to connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit may break 

down or cause a fire.

• Confirm that the outdoor unit are fixed on the base. Otherwise, falling down of the units or other accidents may occur.

Operation

• Do not use this air conditioner for special purpose such as preserving food, precision instruments, art objects, breeding 

animals, car, vessel, etc.

• Do not touch any switches with wet finger, otherwise you may get an electric shock.
• If the air conditioner will not be used for a considerably long time, turn off the main switch or the circuit breaker, for safety.
• To make the air conditioner operate in its original performance, operate it within the range of the operating temperature 

specified in the instructions. Otherwise it may cause a malfunction, or water leak from the unit.

• Prevent any liquid from falling into the remote controller. Do not spill juice, water or any kind of liquid.
• Do not wash the air conditioner. Doing so may result in electric shock.
• Check whether the installation base and other equipment have become deteriorated after being used for a long time. 

Leaving them such condition may result in the unit’s falling down and causing injury. 

• Do not leave flammable sprays or other flammable materials near the air conditioner, and do not spray flammable aerosol 

directly to the air conditioner. They may catch fire.

• Be sure to stop running the air conditioner and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

• Ask for cleaning of the air conditioner to be performed by the dealer.

Cleaning the air conditioner in an improper manner may cause damage to plastic parts, insulation failure of electric parts, 
etc. and result in a malfunction. In the worst case, it may result in water leakage, electric shock, smoke emission and fire.

• Do not put a water container such as a vase on the unit.

Water intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric shock.

(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”

„

Information on the transportation, handling and storage of the 
carton

Examples of indication on the carton

Symbol

Description

Symbol

Description

Symbol

Description

Keep dry

Do not drop

Do not lay down

Fragile

Stacking height 
(12 cartons can 
be stacked in 
this case)

Do not walk on 
this carton

This side up

Do not step

Handle with 
care

CAUTION

Injury possibility.
Don’t handle with packing band, or may get injured in case of 
broken band.

Stacking notice.

In case that cardboard boxes protrude out of pallet when 
stacking.
Lay a 10 mm thick plywood over the pallet.

11 cartons

5-EN

6-EN

Summary of Contents for MMY-MAP0501HT8-E

Page 1: ...MMY MAP0801HT8ZG E MMY MAP1001HT8 E MMY MAP1001HT8Z E MMY MAP1001HT8ZG E MMY MAP1201HT8 E MMY MAP1201HT8Z E MMY MAP1201HT8ZG E Cooling Only Model MMY MAP0501T8 E MMY MAP0501T8Z E MMY MAP0501T8ZG E MMY MAP0601T8 E MMY MAP0601T8Z E MMY MAP0601T8ZG E MMY MAP0801T8 E MMY MAP0801T8Z E MMY MAP0801T8ZG E MMY MAP1001T8 E MMY MAP1001T8Z E MMY MAP1001T8ZG E MMY MAP1201T8 E MMY MAP1201T8Z E MMY MAP1201T8ZG E...

Page 2: ...knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigerant handling and piping work o...

Page 3: ...breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you install the unit in a small room take appropriate measures to prevent the refrigerant from exceeding the limit concentration even if it leaks Consult the dealer from whom you purchased the air conditioner when you implement the measures Accum...

Page 4: ... Installation fuse all types can be used must be used for the power supply line of this air conditioner Installation Certainly lay the drain hose for perfect draining Bad drainage may cause flooding in the house and getting furniture wet Make sure to connect the air conditioner to an exclusive power supply of the rated voltage otherwise the unit may break down or cause a fire Confirm that the outd...

Page 5: ... H E Fresh Air Intake MMD AP HFE For details on these models read the owner s manuals that come with the indoor units Air to Air Heat Exchanger with DX Coil Unit MMD VNK HEXE MMD VN HEXE For details on these models read the owner s manuals that come with the indoor units High wall compact MMK AP MH E For details on these models read the owner s manuals that come with the indoor units High wall MMK...

Page 6: ...e room is taken in through here Discharge louver Controls discharge air directions 2 way Cassette Type 1 way Cassette Type MMU AP007 YH to AP012 YH MMU AP015 SH to AP024 SH Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Air filte...

Page 7: ...anding Cabinet Type Floor Standing Concealed Type Floor Standing Type Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Return air grille Air in the room is taken in through here Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille Discharge louver Controls discharge air directions Eart...

Page 8: ...r sensor indicator Displayed when the remote controller sensor is used 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 No function indicator Displayed when the function requested is not available on that model 14 Fan speed indicator Indicates the selected fan speed 15 ...

Page 9: ...d and floor standing cabinet fresh air intake types 8 Operation lamp Lights up during running Blinks when an error occurs or the protective device activates 9 button Turns on the unit when pushed and turns off when pushed again 10 button Operation mode select button Selects desired operation mode 1 8 3 5 2 9 10 6 7 12 4 11 SWING FIX 11 button Unit Louver select button Selects a unit number left an...

Page 10: ...The fan speed selection function is not available for the concealed duct high static type Fan speed is fixed and the indicator is fixed to High SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 2 Heat pump model Heat Dry Cool Fan Dehumidify Cooling only model Dry Cool Fan Dehumidify Low Medium High Auto Changing the set temperature 1 Push the TEMP butto...

Page 11: ...ing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the air conditioner in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations ...

Page 12: ...ioner If the protective device activates the unit s running stops and the operation lamp blinks When the protective device activates the indicator and the check code are displayed on the remote controller The protective device may activate in the following cases During cooling When the air intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air di...

Page 13: ...COOL DRY operation the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Unit select When two or more indoor units are controlled with one remote controller the louver direction can be set for each indoor unit by selecting them individually To set louver direction in...

Page 14: ...display Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 Swing code Swing Horizontal Downward Downward Horizontal Downward Downward Horizontal Horizontal Cyclic swing Recommended for cooling All four louvers swing at different times like waves Setting the louver lock 1 Push and hold the button right side of the button for at least 4 seconds while running is stopped blinks When no unit number is dis...

Page 15: ...ction setting 0000 Smudging reduction position reduces ceiling smudging factory default 0002 Cold draft position Less directly expose your body to cool air 0000 SET DATA UNIT LOUVER Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 No display 4 way cassette type The louver automatically closes when running is stopped In pre heating mode the louver points upward The swing indication appears on the re...

Page 16: ... GOOD GOOD Ceiling type Vertical adjustment The louver automatically points upward when running is stopped In pre heating mode the louver points upward The swing indication appears on the remote controller even in pre heating mode but the actual swing starts only after pre heating is complete Horizontal adjustment 1 way cassette YH series and floor standing types Setting the direction and swinging...

Page 17: ... louvers slightly and point them in your preferred directions 1 2 In this case do not use the auto swing function Floor standing cabinet type Changing the air discharge Follow the procedure below to change the air discharge 1 Remove the two fixing screws of the air discharge The fixing screws are to be reused 2 Insert your hand into the air discharge and pull it up slightly then remove the air dis...

Page 18: ...et bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 20 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp Check periodically Do not cool down too much Close 10Maintenance WARNING For daily maintenance including Air Filter cleanin...

Page 19: ...hapter Wipe with a dry soft cloth If heavily stained wipe off dirt with a cloth soaked in lukewarm water Do not use water to wipe the remote controller Do not use benzine thinner scouring powder chemical cloth etc as those may cause deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then...

Page 20: ... not cooled or warmed sufficiently Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to LOW MED and is the operation mode set to FAN Is the setup temp the appropriate temperature Are COOL and HEAT selected simultaneously indication ...

Page 21: ...APAN Authorized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type Heat Pump Model MMY MAP0501HT8 E MMY MAP0501HT8Z E MMY MAP0501HT8ZG E MMY MAP0601HT8 E MMY MAP0601HT8Z E MMY MAP0...

Page 22: ... 21 MEMO ...

Page 23: ... 22 MEMO ...

Page 24: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: