Description
Compressor breakdown
Compressor error (lockup) MG-CTT error
Current detection circuit error
TD1 sensor miswiring (incomplete insertion)
Activation of low-pressure protection
Low oil level protection
Error in temperature sensor for oil level detection
TD2 sensor miswiring (incomplete insertion)
Oil level detection circuit error
TD3 sensor miswiring (incomplete insertion)
Duplicated indoor header unit
Duplicated outdoor line address
Duplicated priority indoor unit (as displayed on priority indoor unit)
Duplicated priority indoor unit (as displayed on indoor unit other
than priority indoor unit)
Connection of group control cable to standalone indoor unit
Indoor group/addresses not set
Indoor capacity not set
Outdoor capacity not set
Duplicated central control address
Too many outdoor units connected
Error in No. of IPDUs
External interlock of indoor unit
Extended IC error
Indoor fan motor error
Discharge temperature TD1 error
Activation of highpressure SW
Detection of open phase/phase sequence
Inverter DC voltage (Vdc) error (compressor) MG-CTT error
Heat sink overheating error
Indoor overflow error
Indoor fan motor error
Outdoor liquid backflow detection error
Gas leakdetection (TS1 condition)
Gas leak detection (TD condition)
Discharge temperature TD2 error
Discharge temperature TD3 error
4-way valve reversing error
Activation of high-pressure protection
Outdoor fan IPDU error
G-TR shortcircuit protection error
Compressor position detection circuit error
Other indoor error (group follower unit error)
Check Code List
Description
Indoor-remote controller communication error
(detected at remote controller end)
Remote controller transmission error
Indoor-remote controller communication error
(detected at indoor end)
Indoor-outdoor communication circuit error
(detected at indoor end)
Dropping out of indoor unit
Indoor-outdoor communication circuit error
(detected at outdoor end)
Duplicated indoor address
Duplicated master remote controller
Indoor inter- MCU communication error
Automatic address starting error
Indoor unit not found during automatic address setting
Too many indoor units connected
Error in communication between indoor header and follower units
Error in number of outdoor header units
Connection to other line found during automatic address setting
Outdoor-outdoor communication transmission error
Duplicated follower outdoor address
Dropping out of outdoor unit
Outdoor follower unit error
IPDU communication error
Indoor TCJ sensor error
Indoor TC2 sensor error
Indoor TC1 sensor error
TD1 sensor error
TD2 sensor error
TE1/TE2 sensor error
TL sensor error
To sensor error
Indoor TA sensor error
Indoor TF sensor error
TS1 sensor error
TH sensor error
Outdoor temperature sensor wiring error (TE1, TL)
Outdoor pressure sensor wiring error (Pd, Ps)
TD3 sensor error
Ps sensor error
Pd sensor error
Other indoor error
Outdoor EEPROM error
Main
remote
controller
H01
H02
H03
H05
H06
H07
H08
H15
H16
H25
L03
L04
L05
L06
L07
L08
L09
L10
L20
L28
L29
L30
—
P01
P03
P04
P05
P07
P10
P12
P13
P15
P17
P18
P19
P20
P22
P26
P29
P31
Main
remote
controller
E01
E02
E03
E04
E06
—
E08
E09
E10
E12
E15
E16
E18
E19
E20
E23
E25
E26
E28
E31
F01
F02
F03
F04
F05
F06
F07
F08
F10
F11
F12
F13
F15
F16
F22
F23
F24
F29
F31
07
Check Codes Displayed on Remote Controller and SMMS-i Outdoor Unit
(7-Segment Display on I/F Board) and Locations to Be Checked