42
Models: MMD-AP0721HFE and MMD-AP0961HFE
B
A
U
2
U
1
U
2
U
1
2
3
1
2
1
2
1
2
3
4
5
1
6
5
4
3
2
1
2
1
3
1
2
1
2
1
2
1
3
1
2
1
2 3
1
2
1
2
1
2
1
2 3
1
3
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
5
4
3
2
1
3
1
3
1
3
2
1
2
1
3
1
2
1
2
1
2
1
Option
(Option)
8
7
RED
RED
WHI
TF
Fan drive
T10
ORN
BLU
TC2
TCJ
TA
TC1
CN103
(GRN)
PNL
EXCT
Filter
CN100
(BRW)
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
CN030
(RED)
FS
Fan motor inside wiring diagram
Motor over heating protection switch
RED
WHI
GRY
BLK
BLU
ORN
LM
CN033
(GRN)
3
1
3
1
Fan
CN083
(WHI)
DP
CN068
(BLU)
1
3
5
7
9
7
Surge absorber
UL
L
M
H
RY007
P301
RY006
RY005
RY002
RY001
CN304 (GRY)
CN309 (YEL)
CN067 (BLK)
CN066 (WHI)
Fuse
T5.0A, 250V ~
RED ACIN
WHI
RY004
BLK
1
3
1
3
1
1
1
2
2
3
1
3
1
3
1
3
5
4
3
2
6
5
4
3
2
6
2
1
3
4
5
2
1
3
4
1 1
6 6
5
PMV
43F2
8
7
RED
WHI
43F1
DP
CN080
(GRN)
CN073
(RED)
CN070
(WHI)
CN081
(BLK)
CN082
(BLU)
CN060
(WHI)
CN032
(WHI)
CN061
(YEL)
CN075
(WHI)
CN074
(WHI)
CN050
(WHI)
CN041
(BLU)
CN040
(BLU)
BLU
BLK BLK
BLU
EMG
Line filter
Remote
controller
board
Outdoor unit
F2
YEL
Indoor unit
earth screw
Power supply
220 – 240V ~ 50Hz
220V ~ 60Hz
Closed-end
connector
4P (WHI)
RC2
4P (WHI)
Connector
Remote controller
RED
RED
RED
RED
WHI
WHI
WHI
RED
WHI
RED
G
R
Y
WHI
RED
G
R
Y
WH
I
R
ED
G
R
Y
WH
I
R
ED
G
R
Y
RED
T10A, 250V ~
CN044
(BRW)
Power
supply circuit
Sub P.C. board
MCC-1520
CN02
(YEL)
CN01
(WHI)
TR1
Control P.C. Board
for Indoor Unit
MCC-1403
B
A
BLK
Parts name
Fan Motor
Running Capacitor
Transformer
Intake air temp. sensor
Blow temp. sensor
Temp. sensor
Fan motor control relay
Drain control relay
Pulse Motor Valve
Fuse for fan motor
Fan motor control relay
Drin Pump motor
Float Swotch
Symbol
FM1, FM2
RC1, RC2
TR1
TA
TF
TC1, TC2, TCJ
RY005 ~ 007
RY002
PMV
F1, F2
43F1, 43F2
DP
FS
Terminal block No.
F1 (Low static pressure tap)
F2 (Intermediate static pressure tap)
F3 (High static pressure tap)
F4
Fan motor wiring
Blue (50/60Hz)
Orange (50/60Hz)
Bkack (50/60Hz)
—
Note
At shipment from factory
—
GRY : GRAY
PNK : PINK
ORN : ORANGE
BRW : BROWN
G & Y : GREEN & YELLOW
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
1.
indicates the terminal block.
Latter at inside indicates the terminal number.
2.
A dotted line and broken line indicate the wiring at site.
3.
indicates the control P.C. board.
4.
When installing the drain pump connect the froat switch connector to CN030 connector.
5.
A position is connected to terminal block when change to static pressure.
Exchange the lead wire of arrow ( ) pisition after the terminal number as figure and
lead wire’s color of fan motor.
ORN
BLU
BLK
A
S(N)
R(L)
F1
RED
T10A, 250V ~
5
43F1
3
6
43F2
4
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
FM2
1
2
3
F
1
F
2
F
3
F
4
Fan 2
G & Y
ORN
BLU
4P (WHI)
RC1
4P (WHI)
WHI
RED
G
R
Y
WHI
RED
G
R
Y
WH
I
R
ED
G
R
Y
WH
I
R
ED
G
R
Y
ORN
ORN
BLK
ORN
BLU
BLK
A
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
FM1
1
2
3
F
1
F
2
F
3
F
4
Fan 1
G & Y
49F
Sold separately
Color Identification
6
7
8
5
6
43F1
4
Surge absorber