ADJUSTMENT
5 - 10
[B] Adjustment
Simplex copying:
(1) Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
Fig. 5-20
(2) If the image skew is "C" as shown in the figure below, shift the aligning plate in the direction of
"+", and if "D", shift it to "-".
Fig. 5-21
Fig. 5-22
Shift the aligning plate in the direction of "+".
Shift the aligning plate in the direction of "-".
C
D