17
Section
3. Calibration
3-1 The items need to be calibrated
Change parts
Part
Code
LCD EVF
Sensitive
Aperture
Shutter
Defect pixel
White balance
Focus Strobe
Firmware
update
Lens Module
H100
-
-
o
o
-
-
Color
LCD
H200
o - - - - -
Electric View
Finder
H220 -
o
-
-
-
-
Photo Sensor
H500
-
-
-
-
o
-
Main
PCB U100
o o o o o o
Flash PCB KIT
U300
-
-
-
-
o
-
LCD PCB
U410
o
o
-
-
-
-
Switch
PCB
U500
- - - - - -
Mode
PCB
U510
- - - - - -
Shutter
PCB
U600
- - - - - -
Internal Data
format damaged
o
o o o o o o
o:Need to be calibrated
3-2 Equipments
1) Light Source
LSB-6DM/10 manufactured by TSUBOSAKA ELECTRIC CO, LTD. or equivalent
Light value : 12 +/-0.1LV
Color temperature : 5100 +/- 300K
2) Oscilloscope
Input: 2 inputs and a trigger input (total 3 inputs)
3) Collimator Lens
DLB-50-450PM manufactured by SIGMA KOKI CO, LTD.
f = 450mm
4) Focus Test Chart
Supplied as PDF file “TEST_CHART.pdf” used by printing on A3 size.
5) Power Supply: AC Adapter
AC adapter or DC power supply set to 5.0V/3A
6) USB cable (accesory)
7) Dark room
Prepare an environment allowing a complete light sealed for a distance of 0.9m.
8) 18% Gray Chart
Size: 1m(W) * 1m(H) or more.
9) Calibration Firmware
File Name: “PDR_M500.bin”
For calibration only, not for update.