Q9 ASD Quick Start Guide
25
Figure 21. The Q9 ASD Electronic Operator Interface Features.
EOI Features
LCD Screen
— Displays configuration information, performance data (e.g., output frequency, bus
voltage, torque, etc.), and diagnostic information.
Rotary Encoder
— Used to access the Q9 ASD menu selections, change the value of a displayed
parameter, and performs the
Enter
key function. Turn the
Rotary Encoder
either clockwise or
counterclockwise to perform the
Up
or
Down
functions of the displayed menu selection. Press the
Rotary
Encoder
to perform the
Enter
(select) function.
Local/Remote Key
— Toggles the system to and from the
Local
and
Remote
modes. The LED is on
when the system is in the
Local Command
mode. The
Local
mode allows the
Command
and
Frequency
control functions to be carried out via the
EOI
.
The
Remote
mode enables the
Command
and
Frequency
control functions to be carried out via the
Terminal Board
,
RS485
,
Communication Card
,
or
Pulse Input
. The selection may be made via
Program
Utility Group
Command Mode
and
Frequency Mode 1
, respectively.
ESC Key
— Returns the system to the previously viewed menu item. Subsequent
Escape
key activation
scrolls through the
Root Menu
until reaching the
Frequency Command
screen (See
Figure 22 on pg.
27
). Further
ESC
key entries are ignored.
Run Key
— Issues the
Run
command while in the
Local
mode. The
Run
key LED Illuminates green
while stopped. Illuminates red while running or while exciting the motor.
Mode Key
— Provides a means to access the five root menus. Pressing the
Mode Key
key repeatedly
loops the system through the five root menus (See
Figure 22 on pg. 27
). While looping through the root
menus, the
Program
menu will display the default
Program
root menu screen item or the
Program
sub-
menu item being accessed prior to pressing the
Mode
key.
Stop-Reset Key
— This key has three functions.
1. Issues the
Off
command (decelerates to
Stop
at the programmed rate; F721) if pressed once while
in the
Local
mode.
2. Initiates an
Emergency Off
Fault
if pressed twice quickly from the
Local
or
Remote
modes. The
Emergency Off
function terminates the Q9 ASD output and will apply the stopping method
selected at
F603
.
3. Resets active
Faults
and/or active
Alarms
if pressed twice quickly. The source of the
Fault
or
Alarm
must be determined and corrected before normal ASD operation can resume.
Rotary Encoder
Local/Remote
Mode
Key
Escape Key
Stop-Reset Key
Key (LED)
Run Key
(LED)
Terminal...
Direct Access...
...
Protection...
Fundamental...
LCD Screen
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com