3.24 Running Test
3 Tests and Diagnostics
QOSMIO G30 Maintenance Manual (960-546)
[CONFIDENTIAL]
3-57
3.24 Running
Test
3.24.1 Function
Description
Some devices is tested in an attended operation. The name of tested devices and subtest
number are displayed on the screen while executing the test.
The following message is displayed before the test.
1 - Printer wrap around test (Y/N)?
2 - Serial#A wrap around test (Y/N)?
3 - FDD test (R:read/W:read-write)?
Y: The test is executed.
N: The test is not executed.
R: The sequential read is selected
W: The sequential read/write is selected
This function automatically executes the following tests in sequence:
1.
System test (subtest 01)
2.
Memory test (subtests 01, 02, 06)
3.
Display test (subtest 01)
4.
Real timer test (subtest 02)
5.
HDD test (subtests 01)
6.
FDD test (subtests 02)
The system automatically detects the number of floppy disk drives connected to the computer
for the FDD test.
3.24.2 Operations
1.
Select
6
from the Diagnostic Menu and press
Enter
,
the following messages will
appear in the display in order.
FDD write/read test (Y/N) ?
Printer wrap around test (Y/N) ?
Serial wrap around test (Y/N) ?
CD-ROM/DVD-ROM test (Y/N) ?
2.
To execute the test, press
Y (yes)
and
Enter
. To cancel the test, press
N (no)
and
Enter
. If you execute the selectable test, follow the indication message in the display.
3.
After setting the selectable test, the test starts automatically. To terminate the program,
press
Ctrl + Break.
Summary of Contents for Qosmio G30
Page 10: ...x CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 40: ...1 Hardware Overview 1 9 AC Adapter 1 26 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 41: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 42: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 2 ...
Page 46: ...2 Troubleshooting Procedures 2 vi CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 125: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 126: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 3 ...
Page 228: ...3 Tests and Diagnostics 3 31 SETUP 3 98 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 241: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 242: ...4 Replacement Procedures 4 ii CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 4 ...
Page 353: ... CONFIDENTIAL Appendices ...
Page 354: ...Appendices App ii CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 378: ...Appendices Appendix B Board Layout B 10 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 414: ...Appendices Appendix C Pin Assignments C 36 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...
Page 426: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 511 ...
Page 432: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL QOSMIO G30 Maintenance Manual 960 546 ...