Page 18
User Manual
NOTICE
Be sure to reinstall the bottom drain plug fi rmly to prevent
leakage before using the unit.
NOTICE
Because this unit contains a condensate pump, the drain hose can
be elevated up to 6 ft. (1.8 m). Direct the hose toward the drain,
making sure there are no kinks that will restrict water fl ow. Make
sure the end of the hose is directed downward (see fi g.
with
check mark symbol).
The fi gure with
X
symbol is not recommended as the end of the
hose is not directed downward. When the continuous drain hose
is not used, ensure that the corresponding drain plug and knob
are installed fi rmly to prevent leaks.
Drain hose
adaptor
Press the power
cord buckle into
the rear cover.
Drain
hose
adaptor
Delivery lift < 6ft
X
Remove
the middle
drain plug
Continuous
drain hose
Drain
hose adaptor
•
While operating in heat pump mode, the unit will produce
condensate that must be drained. You must install the drain hose
when operating in heat mode. To install the drain hose, remove
the plug from the drain port and attach the included hose.
The universal drain adaptor can be attached to the end of the
included hose. A 3/4” hose (not included) can be attached to the
adaptor if a longer hose length is required. Place the end of the
hose in the drain area you are using.
•
When the water level of the bottom tray reaches a predetermined
level, the unit beeps 8 times. The digital display shows “P1.” At
this time the air conditioning/dehumidifi cation process will
immediately stop. However, the fan motor will continue to operate
(this is normal). Carefully move the unit to a drain location, remove
the bottom drain plug and let the water drain away. Reinstall the
bottom drain plug and restart the machine until the “P1” symbol
disappears. If the error repeats, call for service.
Installa
tion
Instruc
tions
Water Drainage (For Heating Mode)