background image

4

4 mm

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

1.  Die-cutting front panel slit

  Cut out the slit on the leftward or right side of the front panel for the left 

or right connection and the slit on the bottom left or right side of the front 
panel for the bottom left or right connection with a pair of nippers.

How to remove the drain cap

Clip the drain cap by needle-nose 
pliers and pull out.

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

fi

 rmly until the connection part contacts with heat 

insulator, and then secure it with original screw.

How to 

fi

 x the drain cap

1)  Insert hexagon wrench (4 mm) 
  in a center head.

2)  Firmly insert the drain cap.

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  After scribing slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

In case of bottom right or bottom left piping

•  After scribing slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 43 mm above the wall 

surface. If the connecting pipe is laid exceeding 43 mm above the wall 
surface, the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so 

as not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (

fi

 gure)

How to install the air inlet grille on the indoor 
unit

•  When attaching the air inlet grille, 

the contrary of the removed 
operation is performed.  

Wiring Connection

Wiring of the connecting cable can be carried out without removing the 
front panel.

1.  Remove the air inlet grille.
  Open the air inlet grille upward and pull it toward you.
2.  Remove the terminal cover and cord clamp.
3.  Insert the connecting cable (according to the local cords) into the pipe hole 

on the wall.

4.  Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 15 cm from the front.

5.  Insert the connecting cable fully into the terminal block and secure it tightly 

with screws.

6.  Tightening torque : 1.2 N·m (0.12 kgf·m)
7.  Secure the connecting cable with the cord clamp.
8.  Fix the terminal cover, rear plate bushing and air inlet grille on the indoor 

unit.

     

How to connect the connecting cable

•  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

•  Check local electrical cords and also any speci

fi

 c wiring instructions or 

limitations. 

 

NOTE

•  Use stranded wire only.
•  Wire type : More than H07RN-F or 60245 IEC66 (1.5 mm

2

 or more)

CAUTION

CAUTION

Cord clamp

Terminal block

Terminal cover

Screw

Earth line

Screw

Connecting cable

Screw

Rear right

Rear left

Bottom left

Left

Bottom right

Right

Die-cutting

front panel slit

Changing

drain hose

Piping preparation

Heat insulator

Drain hose

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage of the plug.

Insert a hexagon
wrench (4 mm).

No gap

80

  

270 mm

230 mm

43 mm

Liquid side

Gas side

(To the forefront of 

fl

 are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)

core or the like for bending pipe.)

Use the handle of screwdriver, etc.

Slit

Slit

 

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.
After passing the connecting pipe through the pipe hole, connect the 
connecting pipes to the auxiliary pipes and wrap the facing tape around 
them.

Connecting 
cable

about 15 cm

Earth line

Stripping length of the connecting cable

110 mm

50 mm

10 mm

10 mm

2.  Changing drain hose

  For leftward connection, bottom-leftward connection and rearleftward 

connection’s piping, it is necessary to change the drain hose and drain 
cap.

Summary of Contents for RAS-077SAV-E6

Page 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH Indoor unit RAS 077 107 137 167SKV E7 Outdoor unit RAS 077 107 137SAV E6 RAS 167SAV E5 1115551127 ...

Page 2: ...ectrical Work 3 Wiring Connection 4 Piping and Drain Hose Installation 4 Indoor Unit Fixing 5 Drainage 5 OUTDOOR UNIT 5 Installation Place 5 Precautions about Installation in Regions with Snowfall and Cold Temperatures 5 Refrigerant Piping Connection 6 Evacuating 6 Wiring Connection 7 OTHERS 7 Gas Leak Test 7 Remote Control A B Selection 7 Test Operation 7 Auto Restart Setting 7 CONTENTS EN ...

Page 3: ...HAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNACE STOVES ETC WHEN MOVING THE AIR CONDITIONER FOR INSTA...

Page 4: ...re to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Flat head wood screw Remote control holder Vinyl tape Apply afte...

Page 5: ...agram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor...

Page 6: ...the removed operation is performed Wiring Connection Wiring of the connecting cable can be carried out without removing the front panel 1 Remove the air inlet grille Open the air inlet grille upward and pull it toward you 2 Remove the terminal cover and cord clamp 3 Insert the connecting cable according to the local cords into the pipe hole on the wall 4 Take out the connecting cable through the c...

Page 7: ...t block a passage When the outdoor unit is to be installed in an elevated position be sure to secure its feet The allowable pipe length is up to 20 m If the length is over 15 m add 20 g of refrigerant for every additional meter of the pipe length The allowable height of outdoor unit installation site is up to 10 m A place where the drain water does not raise any problems CAUTION 1 Install the outd...

Page 8: ... a vacuum pump with counter flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops If oil inside of the vacuum pump enters the air conditioner which use R410A refrigeration cycle trouble may result 1 Connect the charge hose from the manifold valve to the service port of the packed valve at gas side 2 Connect the charge h...

Page 9: ...usive use with the air conditioner This product can be connected to the mains Connection to fixed wiring A switch which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring CAUTION Check places for the indoor unit Check places for the outdoor unit Information To switch the TEST RUN COOL mode press RESET button for 10 seconds The beeper will m...

Page 10: ...1115551127 ...

Reviews: