TEMPORARY OPERATION

TIMER OPERATION

12

Daily timer allows the user to set both the ON & OFF timers and will be 
activated on a daily basis.

  Setting Daily Timer

Setting the ON Timer

Setting the OFF Timer

1

Press 

:  Set the desired 

ON timer.

Press 

:  Set the desired 

OFF timer.

2

Press 

: Set the timer.

Press 

: Set the timer.

3

Press 

: Cancel the timer.

Press 

: Cancel the timer.

 

During the daily timer is activating, both arrows ( ,  ) are indicated.

Note:

 

Keep the remote control in accessible transmission to the indoor unit; 
otherwise, the time lag of up to 15 minutes will occur.

 

The setting will be saved for the next same operation.

1

Press 

: Set the ON timer.

3

Press 

.

2

Press 

: Set the OFF timer.

4

Press 

 button during 

the (  or  ) mark 

fl

 ashing.

Set the timer when the air conditioner is operating.

11

In case of the misplaced or discharged remote control

 

Pressing the RESET button, the unit can start or 
stop without using the remote control. 

 

Operation mode is set on AUTOMATIC operation, 
preset temperature is 24°C and fan operation is 
automatic speed.

ECO OPERATION

10

To automatically control room to save energy (except in DRY and FAN ONLY mode)

Press 

ECO

 : Start and stop the operation.

Note:

  Cooling operation; the set temperature will increase automatically 1 degree/

hour for 2 hours (maximum 2 degrees increase). For heating operation the set 
temperature will decrease.

PRESET OPERATION

AUTO RESTART OPERATION

To operate at super low fan speed for quiet operation (except in DRY mode)

 Press 

QUIET

: Start and stop the operation.

Note: 

  Under certain conditions, QUIET operation may not provide adequate 

cooling due to low sound features.

For comfortable sleep, automatically control air 

fl

 ow and automatically turn OFF.

 Press 

: Select 1, 3, 5 or 9 hrs for OFF timer operation.

Note:

  The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase). For heating 
operation, the set temperature will decrease.

COMFORT SLEEP OPERATION

16

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

 

Clean the indoor unit and the remote control with a wet cloth when needed.

 

No benzine, thinner, polishing powder or chemically-treated duster.

Air 

fi

 lters

Clean every 2 weeks.

1. Open the air inlet grille.
2. Remove the air 

fi

 lter.

3. Vacuum or wash and then dry them.
4. Reinstall the air 

fi

 lters and close the air inlet grille.

MAINTENANCE

17

QUIET OPERATION

15

14

To automatically restart the air conditioner after the power failure (Power of 
the unit must be on.)

Setting

  1. Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds)

  2. Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation. (3 beep sound but OPERATION lamp does not 
blink)

 

In case of ON timer or OFF timer are set, AUTO RESTART OPERATION 
does not activate.

13

Set your preferred operation for future use. The setting will be memorized by 
the unit for future operation (except air

fl

 ow direction).

  1. Select your preferred operation.

  2. Press and hold 

 for 3 seconds to memorize the setting.

The 

P

 mark displays.

 3. 

Press 

: Operate the preset operation.

SELF CLEANING OPERATION 
(COOL AND DRY OPERATION ONLY)

18

To protect bad smell caused by the humidity in the indoor unit.

 1. 

If 

the 

 button is pressed once during “Cool” or “Dry” mode, 

the fan will continue to run for other 30 minutes, then it will turn off 
automatically. This will reduce the moisture in the indoor unit.

  2. To stop the unit immediately, press the 

 more 2 times within 

30 seconds.

The unit does not operate.

Cooling or Heating is abnormally low.

 

The power main switch is 
turned off. 

 

The circuit breaker is 
activated to cut off the 
power supply. 

 

Stoppage of electric current. 

 

ON timer is set.

 

The 

fi

lters are blocked with dust. 

 

The temperature has been set improperly. 

 

The windows or doors are opened. 

 

The air inlet or outlet of the outdoor unit 
is blocked. 

 

The fan speed is too low. 

 

The operation mode is FAN or DRY. 

TROUBLESHOOTING (CHECK POINT)

20

REMOTE CONTROL A-B SELECTION

21

To separate using of remote control for each indoor unit in case of 2 air 
conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.
  2. Point the remote control at the indoor unit.
  3. Push and hold 

 button on the Remote Control by the tip of the 

pencil. “00” will be shown on the display.

 4. 

Press 

MODE

 during pushing 

. “B” will show on the display and 

“00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized.

Note:  1. Repeat above step to reset Remote Control to be A.
 

2. Remote Control A has not “A” display.

 

3. Default setting of Remote Control from factory is A.

1

2

OPERATION AND PERFORMANCE

19

  1.  Three-minute protection feature: To prevent the unit from being activated for 3 

minutes when suddenly restarted or switched to ON.

  2.  Preheating operation: Warm up the unit for 5 minutes before blowing warm air.
  3. Warm air control: When the room temperature reaches the set temperature, 

the fan speed is automatically reduced and the outdoor unit will stop.

  4.  Automatic defrosting: Fans will stop during defrost operation.
  5.  Heating capacity: Heat is absorbed from outdoor and released into the room. 

When the outdoor temperature is too low, use another recommended heating 
apparatus in combination with the air conditioner.

  6.  Consideration for accumulated snow: Select the position for outdoor unit where 

it will not be subjected to snow drifts, accumulation of leaves or other seasonal 
debris.

  7. Some minor cracking sound may occur when unit operating. This is normal 

because the cracking sound may be caused by expansion/contraction of plastic.

 

Note:

 Item 2 to 6 for Heating model 

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room

Temperature

Heating

–15°C ~ 24°C

Less than 28°C

Cooling

–15°C ~ 46°C

21°C ~ 32°C

Dry

–15°C ~ 46°C

17°C ~ 32°C

1118350215_EN.indd   3

1118350215_EN.indd   3

7/12/2559 BE   12:02

7/12/2559 BE   12:02