– 25 –
8-9. ADJUSTING AIR FLOW DIRECTION
8-9-1. Adjustment of Vertical Air Flow Direction
(1) When using the wireless auto louver, the air flow
direction is automatically set to the desired posi-
tion of the last time adjusted during operation.
Fig. 8-15
(2) When you stop operation using the remote con-
troller, the louver is closed.
Fig. 8-16
(3) When setting the air flow direction to your prefer-
ence, hold down the SET LOUVER button of the
remote controller and set the air flow in the direc-
tion you desire.
(4) During cool and dry operation, change the air flow
direction within the range indicated.
Fig. 8-17
Note:
•
In the Cool or Dry operation, remember not to
continue the downward air flowing for a long time
to avoid conceivable dewing on the louver sur-
face and resultant dripping trouble.
•
It is also possible to adjust the air flow direction
by the remote controller even when the wireless
auto louver is in use, but once the air conditioner
operation was stopped and restarted thereafter,
the air flowing direction automatically becomes
horizontal.
•
The air flow cannot be adjusted with the remote
controller when the air conditioner is stopped.
(Also when the ON TIMER is indicated on the
display.)
The air flow direction
is automatically set to
the desired position of
the last time adjusted.
When the cooling
or dry operation,
set the louver in
the blue zone.
Louver indicator