– 20 –
FILE NO. SVM-04022
5-3. RAS-07NKHD-E / RAS-07UAH-E3
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
PH80T1-4C
Cooling
Heating
Mark( )means check points of Gas Leak.
O.D.:9.52mm
O.D.:6.35mm
Cooling
Heating
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
9.52
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R-22 : 0.62 kg.
Accumulator
Heat exchanger
Capillary tube
∅
1.0x800
S
(2 pcs.)
Standard
1.35
35.0
High
20/–
7/6
Heating
Overload
1.85
49.0
Low
27/–
24/18
Low temperature
1.10
30.0
High
20/–
–10/–10
Standard
0.58
12.0
High
27/19
35/24
Cooling
Overload
0.67
16.0
High
32/23
43/26
Low temperature
0.50
2.0
Low
21/15
21/15
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
50Hz
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor