– 3 –
FILE NO. SVM-04022
MODEL
RAS-13NKHD-E/ RAS-13UAH-E 3 RAS-13NKD-E / RAS-13UA-E3
ITEM
Cooling
Heating
Cooling
Capacity
220 V
240 V
220 V
240 V
220 V
240 V
kW
3.55 3.60 4.40 4.45 3.70 3.75
Phase 1
∅
Power source
V
220
−
240
Hz
50
Power consumption
kW
1.27
1.32
1.26
1.33
1.24
1.28
Power factor
%
98
96
98
96
98
95
Running
Indoor
A
0.15
current
Outdoor
A
5.75
5.60
5.70
5.65
5.75
5.60
Starting current
A
25
24
Moisture removal
lit/h
2.0
Noise
Indoor (H/M/L)
dB
41/35/31
Outdoor (220
−
240 V) dB
49
51
49
51
47
48
Refrigerant
Name of refrigerant
R22
Rated amount
kg
1.00
0.80
Refrigerant control
Capillary tube
Gas side size
mm
∅
12.7
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
1
(One way)
Maximum height
difference
INDOOR UNIT
RAS-13NKHD-E RAS-13NKD-E
Height mm
275
Dimensions Width
mm
790
Depth mm
218
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
630
650
630
Air volume
Medium fan
m
3
/h
520
550
520
Low fan
m
3
/h
430
490
430
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-13UAH-E3
RAS-13UA-E3
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight
kg
37
34
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h 2120
2200
2120 2200 2030 2150
Fan motor output
W
42
Compressor
Model PH170T2-4L2
PH225X2C-4FT
Output
W
1100
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°C
15 ~ 43
−
10 ~ 24
15 ~ 43
1. SPECIFICATIONS
m
m
6
30
15*