FILE NO. SVM-04022
– 73 –
How to remove the electrical part
1) Remove the front panel with procedure
1
.
2) Remove the screw holding the electrical part
cover.
3) Disconnect the 2 connectors (3P) for the fan
motor, the connector (5P) for the louver
motor from the P.C. board assembly and the
connector (4P) for eletrical supply.
4) Pull out the TC sensor from the sensor
holder.
5) Remove the screw for the ground connection,
remove the screw for the electrical part box
and LED unit. Then remove the LED unit and
the electrical part box from the main unit.
How to mount the electrical part
1) To put back the electrical part box, lock it to
the upper hook of the back body.
2) Tighten the screw on the electrical part box.
3) Connect the 3 connectors and arrange the
wiring same as original condition and then
tighten the screw from the LED unit to the
back body.
4) Attach the TC sensor to the holder.
5) Tighten the screw for the ground connection.
6) Tighten the screw on the electrical part cover.
1) Remove the front panel following procedure
1
.
2) Remove the center shaft of the horizontal
louver from the back body.
3) Remove the left shaft from the back body.
4) Remove the horizontal louver from the back
body.
No.
Part name
Procedures
Remarks
5
Screw
4
TC Sensor
2 Connectors
2
Electrical part
3
Horizontal
louver
5
Screw
2
Center shaft
3
Left shaft
2
Screw
3
3
Connector