FILE NO. SVM-04022
– 75 –
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and Electric
parts cover.
(3 Screws
∅
4 x 10L)
3) Remove the cord clamp (2 Screws
∅
4 x 22L)
and disconnect the connecting cable.
4) Remove the upper cabinet (4 Screws
∅
4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(3 Screws
∅
4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
10-2. Outdoor Unit
1
Common
procedure
No.
Part name
Procedures
Remarks
Cord clamp
3 Screws
∅
4 x 10L
2 Screws
∅
4 x 22L
Electric
parts cover
Packed valve cover
Upper
cabinet
Front
cabinet