Operation display
ON
OFF
OFF
FCU fan
ON ON
OFF
rpm is depend on presetting.
(SL)
FCU louver OPEN
OPEN (12.7º)
CLOSE
Timer display
ON or OFF
ON
ON or OFF
depend on presetting of timer function.
depend on presetting of timer function.
Compressor
ON or OFF
OFF
OFF
depend on presetting per room temperature.
CDU fan
ON or OFF
OFF
OFF
depend on presetting per room temperature.
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning mode
operate
2
0 mins.
Automatically turn-off.
Operation time
Turn off by remote controller or
timer-off function.
How to set Self-Cleaning function
To set the Self-Cleaning function, proceed as follows.
•
Press [RESET] button one time or use remote
control to turn on air conditioner. Display will show
in green color.
•
Hold down the [RESET] button for more than
20 seconds. (The air conditioner will stop suddenly
when the [RESET] is pressed but keep holding it
continue. Then will beep 3 times is the first 3
seconds but it is not related to Self-Cleaning
function)
•
After holding about 20 seconds, the air conditioner
will beep 5 times and OPERATION display blinks
5 times.
•
The Self-Cleaning function had been set.
Remark
Presetting of Self-Cleaning function above, AUTO-
RESTART function had been cancelled. To set
AUTO-RESTART again.
7-
14-1
.
Self-Cleaning diagram
How to cencel Self-Cleaning function
To cancel the Self-Cleaning function, proceed as
follows:
•
Press [RESET] button one time or use remote
control to turn on air conditioner. Display will show
in green color.
•
Hold down the [RESET] button for more than
20 seconds. (The air conditioner will stop suddenly
when the [RESET] is pressed but keep holding it
continue. The will beep 3 times in the first
3 seconds but it is not related to Self-Cleaning
function)
•
After holding about 20 seconds, the air conditioner
will beep 5 times without any blinking of display.
•
The Self-Cleaning Operation had been cancelled.
Remark
Presetting of Self-Cleaning function above, AUTO-
RESTART function had been cancelled. To set
AUTO-RESTART again.
7-
14-2
.
Self-Cleaning function release
How to cencel Self-Cleaning function
To cancel the Self-Cleaning function,
proceed as follows :
FILE NO. SVM-07023
−
29
−
RESET button