− 43
−
FILE NO. SVM-07023
8-5-4. Wiring connection
1.
Remove the valve cover from the outdoor unit.
2.
Connect the connecting cable to the terminal as
identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.
3.
When connecting the connecting cable to the
outdoor unit terminal, make a loop as shown in the
installation diagram of indoor and outdoor unit, to
prevent water coming in the outdoor unit.
4.
Insulate the unused cords (conductors) from any
water coming in the outdoor unit. Proceed them so
that they do not touch any electrical or metal parts.
<Stripping length of connecting cable>
For RAS-07S2AH-E
Fig. 8-5-9
CAUTION
Terminal block
Screw
Earth line
Connecting
cable
Terminal
screw
Cord clamp
75 mm
10 mm
10 mm
65 mm
CAUTION
•
Wrong wiring connection may cause some
electrical parts burn out.
•
Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
•
Every wire must be connected firmly.
NOTE
•
Wire type : H07 RN-F or 245 IEC66 (2.0 mm
2
or more)
For RAS-10S2AH-E
Fig. 8-5-10
Terminal block
Screw
Earth line
Connecting
cable
Terminal
screw
Cord clamp
100 mm
10 mm
10 mm
50 mm
Earth
line
Earth
line
8-6. How to Set Remote Contr
Remote Control B Setup
1) Press RESET button on the indoor unit to turn
ol Selector
A or B
When operating one indoor unit in a situation where
two indoor units have been installed in the same
The indoor unit on which the remote controller
selection has been set to B receives the signal
of the remote controller also set to B.
(At the factory the remote controller selection is
set to A on all the indoor units. There is no
The remote control signal is not recived when the
indoor unit setting is different from the remote
control one.
·
·
room or nearby rooms, this operation prevents the
remote controller signal from being received
simultaneously by both units, thus preventing both
units from operating.
A setting display.)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from factory is A.
the air conditioner ON.
Control by the tip of the pencil. "00" will be shown
2) Point the remote control at the indoor unit.
3) Push and hold CHK button on the Remote
·
on the display.
show on the display and "00" will disappear and
4) Press MODE during pushing CHK . "B" will
the air conditioner will turn OFF. The Remote
Control B is memorized.
·
·
Fig. 8-6-1
SLEEP
PRESET
ONE-TOUCH
FAN
QUIET
SWING
TIMER
FIX
Hi-POWER
ECO
COMFORT
SLEEP
MODE
ON
OFF
SET
CLR
“B” Display
“00” Display