44
−
FILE NO. SVM-07023
8-7. Others
8-7-1. Gas leak test
Fig. 8-7-1
•
Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
8-7-2. Test operation
To switch the TEST RUN (COOL) mode, press
RESET button for 10 sec.
(The beeper will make a short beep.)
8-7-3. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart function
in the off position. Turn it on as required.
<How to set the auto restart>
•
Press and hold the RESET button for about
3 seconds. After 3 seconds, the electronic beeper
makes three short beeps to tell you the Auto
Restart has been selected.
•
To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner’s Manual.
Valve stem cap
connection
Service cap
connection
Valve cover
Fig. 8-7-2
RESET button