– 1
1 –
FILE NO. SVM-07021
5-2. RAS-09SKSX / RAS-09SASX
Ambient temp.
conditions DB/WB
(
°
C)
Indoor
Outdoor
Standard 0.50 11.0 High 27/19.5 35/24
Cooling Overload 0.60 1
5.0 High 32/23 43/26
Low temperature 0.4
0 2.2 Low 21/15 21/15
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (
°
C)
Fan speed
(indoor)
50Hz
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
Capillary tube
∅
1.5x
700
s
QK164PBA
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:9.52mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
9.52
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R22 :
0.58 kg.
Note
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)