4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
(RAS-07SKSX, RAS-09SKSX)
4-2.
Outdoor Unit (RAS-
07S2AX)
No.
Parts name
Type
Specifications
Output (Rated)
6
0
5
W, 2 poles, 1 phase, 220 – 240V
~, 50Hz
1 Compressor
PH
1
0
8X1C
-4
DZDN2
Winding resistance (
Ω
) C-R C-S
(at 20°C)
4.8
4
4.40
Output (Rated)
2
0W, 6 poles, 1 phase, 220 – 240V, 50Hz
2
SK
F-240-20B
Winding resistance (
Ω
) Red-Black White-Black
(at 20°C)
235.2
260.1
3
Running capacitor
DS451155
N
PQ
B
AC 450V~, 1.5
µ
F
(for fan motor)
4
Running capacitor
RS44B256U0213S
AC
44
0V~,
2
5
µ
F
(for compressor)
(for outdoor)
Fan motor
Overload relay
5
JMRA99208-9102
U/T: 4.2A (80°C), Open: 135±5°C, Close: 69±11°C
No.
Parts name
Type
Specifications
1 Fan motor (for indoor)
AFS
-2
2
0-20-4
AR
AC Motor with 1
45
°C thermo fuse
2 Thermo sensor (TA-sensor) 10k
Ω
at 25°C
3
Micro power module (M01) RM1260V
AC220
- 240V~, 50/60Hz
4 Microcontroller unit (IC30)
TMP87CM40A
FG-6P69
5
Heat exchanger sensor
10k
Ω
at 25°C
(TC-sensor)
6 Bridge rectifier (DB
01
)
DB105G 1A, 600V
7 Capacitor (C
63) EKMH401VSN470MP20S 47
µ
F, 4
00
V
8 Fuse (F01) BET6.3A 6.3A, 250VAC
9 Varistor
(R21, R22)
TN
D15G-561KB0SLAA0
560V
10 Louver motor
24BYJ48
12VDC
11 Relay (Comp., RY01)
G4A-1A-E-CA
20A/250V, 12VDC
12
Line filter (L01) LC*SS11V-06270 27mH, 600mA
µ
13 Resistor (R319) RF-2TK5R6 5.6
Ω
, 2W