4-
5
. Indoor Unit (RAS-13UKP-E
4
, RAS-10UKP-E
4
,
RAS-07UKP-E4,
RAS-13UKPX
4
,
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Transformer
4 Microcontroller unit (IC30) TMP87CM40AN
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600 V
8 Capacitor (C50) PF1E222MNN1625
2200
m
F, 25 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10
Varistor (R21, R22)
15G561K
560 V
1
1
Louver motor MP24
Z
12VDC
1
2
Relay (Comp., RY01)
DI1U
Rating 2
5
A/AC250 V,
3~48
VDC
RAS-10UKPX4,
RAS-12UKPX
4, RAS-07UKPX4
)
W
°
°
°
W
TT-10
4-
6
. Outdoor Unit (RAS-13UA-E
4
)
No.
Parts name
Type
Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220
-
240 V, 50Hz
1 Compressor
PH225X2C-4FT Winding resistance (
W
)
C-R C-S
(at 20 C) 2.35 3.22
Output (Rated) 30 W, 6 poles, 1 phase, 220
-
240 V, 50Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance (
W
) Red-Black White-Black
(at 20 C) 245 388
3
Running capacitor
DS451155BPQC AC 450 V, 1.5
µ
F
°
°
4
Running capacitor
DS371356CPNB AC 370 V, 35 F
(for compressor)
m
-
20
-
FILE NO. SVM-05001