7. OPERATION DESCRIPTION
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcontroller, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [
SWING
] button is pressed
again
,
it stops
swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
+
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which
driving
the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
LOW
+
=
MED
+
=
LOW+MED
2
MED+HIGH
2
−
31
−
The air conditioner is controlled by the controller
mounted in the indoor unit. The controller operates all
components based on the commands transmitted from
the remote control and the feedback data of the sensor
is as follow:
•
The temperature measurement at the air inlet of
the indoor heat exchanger by the indoor
temperature sensor
•
The temperature measurement at the indoor
heat exchanger by the indoor heat exchanger
temperature sensor
•
Indoor fan motor operation control
•
Louver motor control
•
LED display control
•
Outdoor fan motor operation control
•
Compressor operation control
•
Receiving the information of the operation
status and judging the information or the
indication of errors
FILE NO. SVM-05001
•
4-WAYS-VALVE operation control
(Heat pump model only)
Table 7-1-1
FAN TAP
Cooling
UH
H
M
L
L-
UL
SL
OPERATION
Fan only
H
M
L
L-
Dry
M
L
L-
UL
SL
MODE
Heat
UH
H
M
L
L-
UL
SL
RAS-07
U
K Series
rpm
1350
1300 1200 1050 1000 950 900 800 750 700
650
Air flow volume (m
3
/h)
650
630 570 490 460 430 400 340 310 280
250
RAS-07
UKH
Series
rpm
1300
1200 1050 1000
900
800 750 700
650
Air flow volume (m
3
/h)
630
570 490 460
400
340 310 280
250
RAS-10
UK
Series
rpm
1350
1250 1050 1000 950 900 800 750 700
650
Air flow volume (m
3
/h)
650
610 490 460 430 400 340 310 280
250
Model RAS-10
UKH
Series
rpm
Air flow volume (m
3
/h)
RAS-13
UK
Series
rpm
Air flow volume (m
3
/h)
RAS-13
UKH
Series
rpm
Air flow volume (m
3
/h)
1250
610
1300
630
1300
1200 1100 1000
900
800 750 700
650
630
570 520 460
400
340 310 280
250
1250
610
1350
1300 1150 1100 1050 1000 950 900 850
750
650
630 550 520 490 460 430 400 370
310
800
340
700
280
1350
1300 1150 1100 1050 1020 950 900 850
750
650
630 550 520 490 470 430 400 370
310
800
340
700
280