– 30 –
FILE NO. SVM-02005(1)
Notch
<Stripping length of the connecting cable>
Fig. 8-4-7
NOTE
•
Use standard wire only.
•
Wire type : H07 RN-F or more
<Taking out the power cord>
Fig. 8-4-8
•
Put the power supply cord through the notch.
8-4-4. Wiring connection
<How to connect the power cord>
For the air conditioner that does not have power
cord, connect a power cord to it as mentioned
below.
(1) Open the air inlet grille upward.
(2) Remove the four screws securing the front panel.
(3) Slightly open the lower part of the front panel then
pull the upper part of the front panel toward you to
remove it from the rear plate.
(4) After removing the front panel, remove the power
cord connect cover and the cord camp.
(5) Connect and secure the power supply cord and
secure the cord camp and the power connect
cover.
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a file,etc.
Fig. 8-4-5
Fig. 8-4-6
N
L
40 mm
10 mm
30 mm
10 mm
Earth line
Screw
Screw
Power cord
connect cover
Screw
Power supply cord
Earth line
Terminal
block
Cord clamp
Air Inlet grille
3
1
2
Front panel