−
22
−
5-4. RAS-10UKP-ES
4
/ RAS-10U
A-ES4
Note :
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard 0.9
8
11.0 High 27/19 35/24
Cooling Overload 1.1
0
15.0 High 32/23 43/26
Low temperature
0.85
5.0
Low
21/15
21/15
Fan speed
(indoor)
50Hz
Indoor unit
Cross flow fan
Cooling
Cooling Compressor
Heat exchanger
Propeller fan
Outdoor unit
PA108X1
C
-4FZ
DN
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
9.52
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410A : 0.
70
kg.
Heat exchanger
Capillary tube
∅
1.5x1100
l
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
FILE NO. SVM-05020