background image

TOSHIBA RAS-07/10/13UKHP-E (US) 1075000801

OWNER’S MANUAL

MODE D’EMPLOI
BEDIENUNGSANLEITUNG
MANUAL D’ISTRUZIONE
MANUAL DEL USUARIO
MANUAL DO UTILIZADOR

PУКOBOДCTBO ПO ЭКCПЛУATAЦИИ

VLASNIČKI PRIRUČNIK
UŽIVATELSKÁ PŘÍRUČKA
FELHASZNÁLÓI KÉZIKÖNYV

KULLANIM KILAVUZU

RAS-07UKHP-E   / RAS-07UAH-E
RAS-10UKHP-E   / RAS-10UAH-E
RAS-13UKHP-E   / RAS-13UAH-E

Indoor Unit

Outdoor Unit

Unité intérieure

Unité extérieure

Raumgerät

Außengerät

Unità interna

Unità esterna

Unidad interior

Unidad exterior

Unidade Interior

Unidade Exterior

Bнyтpeнний блок

Hapyжный блок

Unutarnja jedinica

Vanjska jedinica

Vnitřní jednotka

Venkovní jednotka

Beltéri egység

Kültéri egység

İç Ünite

Dış Ünite

AIR CONDITIONER 

(SPLIT TYPE)

CLMATISEUR (MODELE SEPARE)
KLIMAGERÄT
(GETEILTE AUSFÜHRUNG)
CONDIZIONATORE D

ARIA

(TIPO SCOMPONIBILE)
ACONDICIONADOR DE AIRE
(TIPO SPLIT)
SISTEMA DE AR CONDICIONADO
(TIPO SPLIT)

КOHДИЦИOHEP BOЗДУХA
(CПЛИT-CИCTEMA)

KLIMATSKI UREĐAJ (RASTAVLJIV MODEL)
KLIMATIZAČNÍ ZAŘÍZENÍ (DĚLENÝ TYP)
LÉGKONDICIONÁLÓ (OSZTOTT TÍPUS)

KLİMA (SPLİT TİPİ)

1075000801

For general public use
Pour utilisation grand public
Für allgemeine Verwendung
Per l’uso in generale
Para el uso público general
Para utilização do público em geral

Oбщeго нaзнaчeния

Za opću javnu primjenu
Pro širokou uživatelskou veřejnost
Általános célú felhasználásra

Evlerde kullanım için

01RAS-07/10/13UKHP_E COVER

1/31/02, 5:41 PM

1

Summary of Contents for RAS-07UAH-E

Page 1: ...ca Vnitřní jednotka Venkovní jednotka Beltéri egység Kültéri egység İç Ünite Dış Ünite AIR CONDITIONER SPLIT TYPE CLMATISEUR MODELE SEPARE KLIMAGERÄT GETEILTE AUSFÜHRUNG CONDIZIONATORE D ARIA TIPO SCOMPONIBILE ACONDICIONADOR DE AIRE TIPO SPLIT SISTEMA DE AR CONDICIONADO TIPO SPLIT КOHДИЦИOHEP BOЗДУХA CПЛИT CИCTEMA KLIMATSKI UREĐAJ RASTAVLJIV MODEL KLIMATIZAČNÍ ZAŘÍZENÍ DĚLENÝ TYP LÉGKONDICIONÁLÓ O...

Page 2: ...ndicionador de air Muito obrigado por ter optado por um Sistema de Ar Condicionado TOSHIBA Leia atentamente este manual antes de utilizar o seu Sistema de Ar Condicionado Блaгодapим Bac зa покyпкy кондиционepa воздyxa TOSHIBA Пожaлyйcтa внимaтeльно пpочитaйтe это pyководcтво пepeд иcпользовaниeм Baшeго кондиционepa Zahvaljujemo se na vašoj kupnji TOSHIBA klimatskog uređaja Molimo pažljivo pročitaj...

Page 3: ...2 SICHERHEITSVORKEHRUNGEN 2 TEILEBEZEICHNUNG 3 BBEZEICHNUNGEN UND FUNKTIONEN DER ANZEIGEN UND REGLER AM RAUMGERÄT 3 DIE FERNBEDIENUNG UND IHRE FUNKTIONEN 4 BEZEICHNUNG UND FUNKTION DER ANZEIGEN AUF DER FERNBEDIENUNG 5 VORBEREITUNGEN UND ÜBERPRÜFUNGEN VOR DEM BETRIEB 5 HANDHABUNG DER FERNBEDIENUNG 7 AUTOMATIKBETRIEB 8 AUTOMATIKBETRIEB AUTOMATISCHER BETRIEBSARTWECHSEL 8 KÜHL HEIZ NUR VENTILATOR BETR...

Page 4: ... O AR CONDICIONADO 15 FUNCIONAMENTO TEMPORÁRIO 16 MANUTENÇÃO 17 FUNCIONAMENTO E DESEMPENHO DO AR CONDICIONADO 19 PROBLEMAS E CAUSAS 20 CARACTERÍSTICAS TÉCNICAS 22 PROBLEMAS E CAUSAS relativos ao controlo remoto 23 ПPИHAДЛEЖHOCTИ КOMПOHEHTЫ BOЗДУШHOГO ФИЛЬTPA 2 MEPЫ БEЗOПACHOCTИ 2 HAЗBAHИЯ COCTABHЫХ ЧACTEЙ 3 HAЗBAHИЯ И ФУHКЦИИ ИHДИКATOPOB И OPГAHOB УПPABЛEHИЯ BHУTPEHHEГO БЛOКA 3 ПУЛЬT ДУ И EГO ФУHК...

Page 5: ...I TEENDŐK 5 A TÁVIRÁNYÍTÓ KEZELÉSE 7 AUTOMATIKUS MŰKÖDÉS 8 AUTOMATIKUS MŰKÖDÉS AUTOMATIKUS VÁLTÁS 8 HŰTÉS FŰTÉS VENTILÁTOR ÜZEMMÓD 9 SZÁRÍTÁS MÓD 9 Hi POWER ÜZEMMÓD 10 IDŐZÍTÉS MÓD 10 MEMÓRIA ELŐRE BEÁLLÍTOTT MŰKÖDÉS 12 A LEVEGŐFÚVÁS IRÁNYÁNAK BEÁLLÍTÁSA 13 AUTOMATIKUS ÚJRAINDÍTÁS FUNKCIÓ 14 A LÉGKONDICIONÁLÓ MŰKÖDÉSE 15 TEMPORARY MŰKÖDÉS 16 KARBANTARTÁS 17 A LÉGKONDICIONÁLÓ ÜZEMMÓDJAI ÉS A TELJES...

Page 6: ...ke contact with the dealer If the air conditioner is continuously operated with something abnormal it may cause machine failure electric shock fire and so on Do not spill water or other liquid on the indoor unit If the unit is wet it may cause an electric shock WARNING ABOUT MOVEMENT AND REPAIR Do not move nor repair any unit by yourself Since there is high voltage inside the unit you may get an e...

Page 7: ...ise you may get an electric shock Do not place any combustion appliance in a place where it is directly exposed to wind of the air conditioner otherwise it may cause imperfect combustion When the air conditioner won t be used for a considerably long time turn off the main switch or the circuit breaker for safety Disconnection from the power supply prevents the unit from lightning and power source ...

Page 8: ...ange The operation lamps flash rapidly five times per second when safety protection features come into operation When the auto restart function is in operation the OPERATION lamp is orange TEMPORARY button If you misplace or lose the remote control or its batteries are exhausted push the TEMPORARY button 1 Open the air inlet grille to push the TEMPORARY button You can lift the grille up to an angl...

Page 9: ...ton to select a mode Each time you press the button a mode is selected in a sequence that goes from A Auto changeover control Cool Dry Heat Fan only and back to A A receiving beep is heard 4 4 4 4 4 Temperature button The set temperature is increased up to 30 C 9 The set temperature is dropped down to 17 C A receiving beep is heard 5 5 5 5 5 Fan speed button FAN Press this button to select fan spe...

Page 10: ...tioning and operation Five selectable positions Automatic Swing 5 5 5 5 5 FAN speed display Indicates the selected fan speed AUTO or one of five fan speed levels LOW LOW MED MED HIGH can be indicated Indicates AUTO when the operating mode is either AUTO or Dry 6 6 6 6 6 TIMER and clock time display The time set for timer operation or clock time is indicated The present time is always indicated exc...

Page 11: ...minute steps 2 2 2 2 2 SET SET button Press the SET SET button The current time is indicated and the clock starts Clock adjusting 1 1 1 1 1 CLOCK button Press the CLOCK button The CLOCK display flashes 2 2 2 2 2 TIMER button Press the TIMER button to set the current time Each press of the TIMER button changes the time by one minute Pressing the TIMER button continually changes the time by ten minu...

Page 12: ...these appliances or consult your local dealer CAUTION Location of the remote control Keep the remote control where its signals can reach the receiver of the indoor unit a distance of 7m is allowed When you select the timer operation the remote control automatically transmits a signal to the indoor unit at the specified time If you keep the remote control in a position that hinders proper signal tr...

Page 13: ...VER When you set the air conditioner in A mode or switch over from AUTO operation because of some settings change it will automatically select cooling heating or fan only operation depending on the room temperature see page 15 Start 1 1 1 1 1 START STOP button Press this button to start the air conditioner 2 2 2 2 2 Mode select button MODE Select A 3 3 3 3 3 Temperature button Set the desired temp...

Page 14: ...ling 21 C or higher Heating 28 C or lower When the air conditioner is in FAN ONLY operation the temperature display is not indicated 4 4 4 4 4 Fan speed button FAN Select one of AUTO LOW LOW MED MED HIGH The OPERATION lamp green on the display panel of the indoor unit goes on And operation starts after approximately 3 minutes if you select FAN ONLY mode the unit will start immediately The Fan only...

Page 15: ...mits the timer signal to the indoor unit at the specified time Therefore keep the remote control in a location where it can transmit the signal to the indoor unit properly If you do not press the SET SET button within 30 seconds after setting the time the setting will be cancelled Hi POWER OPERATION High power Hi POWER The Hi POWER high power operation mode automatically controls room temperature ...

Page 16: ...on which is closer to the current time is activated first If the same time is set for both ON and OFF timers no timer operation is performed Also the air conditioner may stop operating Every day combined timer setting both ON and OFF timer simultaneously and activate every day This feature is useful when you want to use combined timer at the same time every day Setting combined TIMER 1 Press the O...

Page 17: ... if you press another button the MEMORY setting is cancelled Operation modes which can be memorized with the MEMO button are MODE Temperature FAN TIMER and Hi POWER To operate the air conditioner with the setting memorized by the MEMO button 1 1 1 1 1 PRESET button Press the PRESET button The setting memorized with the MEMO button will be indicated and the air conditioner operates with regards to ...

Page 18: ...WING button on the remote control swing icon is indicated in the remote control display To stop the function press the FIX button To change the swing direction press the FIX button and press the SWING button again The FIX and SWING buttons will be disabled when the air conditioner is not in operation including when the ON TIMER is set Do not operate the air conditioner for long hours with the air ...

Page 19: ... air conditioner During the subsequent operation the orange lamp is indicated The auto restart operation will not accept an instruction if timer operation with the remote control is selected The louver swing AUTO operation will not resume after restarting the air conditioner by the AUTO RESTART OPERATION To cancel the auto restart operation proceed as follows Repeat the setting procedure the air c...

Page 20: ...temperature Heating operation In the operation suppression zone where capacity is kept to the minimum overheating is prevented by lowering the temperature setting by 1 C after 1 hour and by 2 C after 2 hours of operation The room temperature is thus regulated between the set temperature and the operation suppression zone Automatic Operation The air conditioner selects and operates in one of the op...

Page 21: ...ired operating time Get uniform circulation of room air Adjust air flow direction for even circulation of room air HINTS FOR ECONOMICAL OPERATION TEMPORARY operation This function is used to operate the unit temporarily in case you misplace the remote control or its batteries are exhausted Push the TEMPORARY button to start the air conditioner While the substitute operation is set the remote contr...

Page 22: ...f a day to dry the inside of the unit 2 Stop the air conditioner and turn off the circuit breaker 3 Remove the batteries from the remote control Check before operation FAN ONLY operation Check that the air filters are installed Check that the air outlet or inlet of the outdoor unit is not blocked CAUTION Cleaning the air filter Clean the air filters every 2 weeks If the air filters are covered wit...

Page 23: ...t arms of the air inlet grille to the shafts on the two sides of the air conditioner and push in completely and then push in the center arm 5 Check that the center arm has been completely inserted and close the air inlet grille Push the arrow locations four at the bottom of the air inlet grille to check whether the grille is completely closed INFORMATION Zeo Lite Filter Expose the zeo lite filter ...

Page 24: ...hen the outdoor temperature is too low to use another heating apparatus in combination with the air conditioner is recommended Consideration for accumulated snow Select the position for the outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris It is important that the air flow of the outdoor unit is not impeded as this will result in reduced hea...

Page 25: ...oner Any other unusual condition is observed CAUTION Before you ask for servicing or repairs check the following points Inoperative The power main switch is turned off The circuit breaker is activated to cut off the power supply The main power fuse has blown out Stoppage of electric current The batteries in the remote control are exhausted ON timer is set Poor cooling or heating performance The ai...

Page 26: ...imes frosted in heating operation In that case the unit automatically performs defrosting for 2 to 10 minutes for raising the heating efficiency In defrosting operation both the indoor and outdoor units stop air flow Hiss sound is heard when flow of the refrigerant is changed for defrosting Resultant water of automatic defrosting in heating operation is drained out of the outdoor unit Air flow cha...

Page 27: ...ling Indoor Unit RAS 10UKHP E Outdoor Unit RAS 07UAH E Outdoor Unit RAS 10UAH E Air inlet temperature C Dry bulb 20 Indoor coil assembly Wet bulb Dry bulb 7 Wet bulb 6 Outdoor coil assembly For heating The specifications may be subject to change without notice for purpose of improvement The specified air conditioning capabilities are based on the data determined under the following conditions Air ...

Page 28: ... temperature cannot be set during fan only operation Symptoms The indication on the display disappears after a lapse of time The TIMER display goes off after a certain period of time Causes Check whether the timer operation has come to an end when the OFF TIMER is indicated on the display Check whether the timer operation has started when the ON TIMER is indicated on the display ON Reason The air ...

Reviews: