FILE NO. SVM-02003
– 29 –
8-2. Installation Diagram of Indoor and Outdoor Units
For installation of the indoor unit, use the paper pattern on the back of the installation manual.
Shield
pipe
Air filter
Be sure to use the
Electric parts cover
Hook
(Attac
h to the fr
ont panel)
2
Wireless remote
control
65 mm or more
170 mm
or more
600 mm or more
B mm or more
A mm or more
8
Pan head wood screw
6
Purifying filter
5
Zeolite filter
4
Remote control holder
Vinyl tape
Apply after
carrying out a
drainage test.
07, 10 class
13 class
A
400 mm
600 mm
B
45 mm
100 mm
(10-13 Class)
(07 Class)
600 mm or more
B mm or more
100 mm or more
A mm or more
600 mm or more
Vinyl tape
Apply after
carrying out a
drainage test.
Saddle
Extension
drain hose
(Option:
RB–821SW)
Hook
170 mm
or more
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Bottom right
Insulate the refrigerant
pipes separately with
insulation, not together.
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
600 mm or more
Extension
drain hose
(Option:
RB–821SW)
1
Installation
plate
100 mm or more
Wall
Left
Rear left
Bottom left
6 mm thick heat resisting
polyethylene foam
Before installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
2
2
2
2
Wireless remote control
Cover
3
3
3
3
3
Batteries
Saddle
Loop the connective cable
(about 100 mm in diameter
and 300 – 350 mm long).
Do not allow the drain hose
to get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping hole
sloped slightly