– 63 –
FILE NO. SVM-02003
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and electric
parts cover.
(2-Screws
∅
4 x 10L)
3) Remove the cord clamp (2-Screws
∅
4 x 22L)
and disconnect the connecting cable.
4) Remove the upper cabinet (4-Screws
∅
4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(7-Screws
∅
4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure
1
.
2) Remove the fixing screw and the capacitor
band.
(1-Screw
∅
4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure
1
.
2) Remove the fixing screw.
(1-Screw
∅
4 x 10L)
3) Disconnect the lead wire
1) Perform the common procedure
1
.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull up
the overload relay.
4) Disconnect the lead wires.
10-4. Outdoor Unit (RAS-07UAX-T2, RAS-10UASX)
1
Common
procedure
2
Capacitor for
compressor
3
Capacitor for
fan motor
4
Overload relay
No.
Part name
Procedures
Remarks
2-Screws
∅
4 x 22L
2-Screws
∅
4 x 10L
For compressor
For fan motor
Overload relay