14
-
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13
N
KHP-E
2
)
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150 C thermo fuse
2
Thermo sensor (TA-sensor)
10k at 25 C
3 Micro Power Module (M01)
4 Microcontroller unit (IC30) TMP87CM40AN
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 47
m
F, 400 V
9 Fuse (F01) BET 6.3A T6.3A, 250VAC
10 Varistor (R21, R22)
TND15G561K
560 V
11 Resistor (R319) RF-2TK5R6 5.6 , 2 W
12 Louver motor MP24Z 12VDC
13 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3-48VDC
14 Relay (Fan, RY03)
G5NB-1A Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04)
G5NB-1A Rating 3A/AC250 V, 12VDC
4-2. Outdoor Unit (RAS-13
N2
AH-E)
No.
Parts name
Type
Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220
-
240 V, 50Hz
1 Compressor PH225X2C-4FT Winding resistance ( ) C-R C-S
(at 20 C) 2.35 3.22
Output (Rated) 42 W, 6 poles, 1 phase, 220
-
240 V, 50Hz
2
Fan motor (for outdoor)
HF-240-42A
Winding resistance ( )
Red-Black
White-Black
(at 20 C)
176.2
290.5
3
Running capacitor
DS451155NPQB AC 450 V, 1.5
m
F
(for fan motor)
4
Running capacitor
RS44B356U0125S AC 440 V, 35
m
F
(for compressor)
W
W
W
W
W
°
°
°
°
°
FILE NO. SVM-06001
µ
RM1260V
DC 390V, Secondary DC 12V