4
–
MODEL RAS-13NKP-E2 / RAS-13N2A-E RAS-13NKPX / RAS-13N2AX RAS-12NKPX-V / RAS-12NAX-V
ITEM
Cooling
Capacity
220 V 240 V 220 V 240 V 220 V 240 V
kW 3.
70
3.
75
3.7
0
3.7
5 3.
4
0 3.
48
Phase
1
Æ
Power source
V
220
-
240
Hz
50
Power consumption kW 1.2
4
1.
28
1.2
4
1.
28
1.24 1.28
Power factor % 9
8
9
5
98 9
5
98 95
Running
Indoor
A
0.15
current Outdoor A 5.
75
5.
6
0 5.
75
5.
60
5.75 5.60
Starting current A
24
Moisture removal
lit/h
2.0
Noise
Indoor (H/M/L) dB 41/35/31
Outdoor (220
-
240 V) dB 4
7
48
4
7
48
47 48
Refrigerant
Name of refrigerant
R22
Rated amount
kg
0.80
Refrigerant control
Capillary tube
Gas side size
mm
Æ
12.7
Connection type
Flare connection
Liquid side size
mm
Æ
6.35
Interconnection Connection type Flare connection
pipe Maximum length
1
(One way)
Maximum height
difference
INDOOR UNIT
RAS-13NKP-E2 RAS-13NKPX RAS-12NKPX-V
Height mm 275
Dimensions Width
mm
790
Depth mm 2
1
8
Net weight
kg
10
Evaporator type Finned tube
Indoor fan type
Cross flow fan
High fan m
3
/h 6
3
0
Air
-flow
volume
Medium fan m
3
/h 5
2
0
Low fan m
3
/h 4
3
0
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13N2A-E RAS-13N2AX RAS-12NAX-V
Height mm 550
Dimensions
Width
mm
780
Depth
mm
270
Net weight kg
3
4
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Air
-
flow volume m
3
/h 2
03
0 2
15
0 2
03
0 2
15
0 2030 2150
Fan motor output
W
Compressor
Model
PH225X2C-4FT
Output
W
1100
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range °C
15 ~ 43
21
~ 43
m
m
6
3
0
15*
FILE NO. SVM-06001