36
–
Item
11. Self-Cleaning
Operation flow and applicable data, etc.
1. Purpose
The
Self-Cleaning
operation is to minimize the
growth of mold, bacteria etc. by running
the fan and drying so as to keep the
inside of the air conditioner clean.
Self-Cleaning operation
When the cooling or dry operation shuts
down, the unit automatically starts the
Self-
Cleaning
operation which is then performed
for the specified period based on duration
of the operation which was performed
prior to the shutdown, after which the
Self-Cleaning
operation stops.
(The
Self-Cleaning
operation is not
performed
after a heating operation.)
2. Operation
1) When the stop signal from the remote
controller or timer
-
off function
is received,
only the timer indicator light.
2) The period of the
Self-Cleaning
operation
is
determined by the duration of the
operation performed prior to the
reception of the stop code.
3) After the
Self-Cleaning
operation has
been
performed for the specified period,
the
unit stops operating.
Unit now performing cooling or dry operation
Press “STOP” button
Only timer indicator lights, and Self Cleaning operation starts
Time set now elapses
Operation stops
function
• During Self-Cleaning operations: The louver opens
slightly. The indoor fan operates continuously at
a speed of 500 rpm.
Cooling: Auto (cooling) Dry
Heating: Auto (heating)
Auto (fan only)
Shutdown
Operation time
Up to 10 minutes
No Self-Cleaning operation
performed (0 minutes)
10 minutes
30 mins.
or longer
No Self-Cleaning operation performed
• To stop an ongoing Self-Cleaning operation at any time
Press the start/stop button on the remote controller twice during the Self-Cleaning
operation. (After pressing the button for the first time, press it for the
Self-Cleaning operation times
second time without delay (within 10 minutes).)
Description
Self-Cleaning operation time
FILE NO. SVM-07008
Summary of Contents for RAS-10N3ACV Series
Page 16: ...FILE NO SVM 07008 15 4 2 Outdoor Unit C L C L ...
Page 17: ... 16 FILE NO SVM 07008 5 WIRING DIAGRAM 5 1 Indoor Unit ...
Page 18: ...FILE NO SVM 07008 17 5 2 Outdoor Unit ...
Page 83: ...FILE NO SVM 07008 82 P C board layout Solder side ...
Page 94: ...FILE NO SVM 03008 87 TOSHIBA CARRIER CORPORATION ...