4
–
2
.
SPECIFICA
TIONS
2
-1. Specifications
Unit model
Indoor
RAS-10SKV-E, RAS-10SKV-A
Outdoor
RAS-10SAV-E, RAS-10SAV-A
Cooling capacity
(kW)
2.5
Cooling capacity range
(kW)
1.1 - 3.0
Heating capacity
(kW)
3.2
Heating capacity range
(kW)
0.9 - 4.1
Power supply
1Ph/50Hz/220-240V
Electric
Indoor
Operation mode
Cooling
Heating
characteristic
Running current
(A)
0.16 - 0.14
0.16 - 0.14
Power consumption
(W)
30
30
Power factor
(%)
87
87
Outdoor
Operation mode
Cooling
Heating
Running current (A) 3.
44 - 3.16 3.96- 3.63
Power consumption
(W)
720
830
Power factor
(%)
95
95
Starting current
(A)
4.12 - 3.77
COP (Cooling / Heating)
3.33
3.72
3.33/3.72
Operating
Indoor
High
(Cooling / Heating)
(dB-A)
38/40
noise
Medium
(Cooling / Heating)
(dB-A)
33/35
Low
(Cooling / Heating)
(dB-A)
29/30
Outdoor
(Cooling / Heating)
(dB-A)
48/50
Indoor unit
Unit model
RAS-10SKV-E, RAS-10SKV-A
Dimen
sion Height (mm) 250
Width
(mm)
740
Depth
(mm)
195
Net weigh
t (kg) 8
Fan motor output
(W)
20
Air flow rate
(Cooling / Heating)
(m
3
/ min)
8.7/9.6
Outdoor unit
Unit model
RAS-10SAV-E, RAS-10SAV-A
Dimen
sion Height (mm) 530
Width
(mm)
660
Depth
(mm)
240
Net weigh
t (kg) 29
Compressor
Motor output
(W)
750
Type
Single rotary type with DC-inverter variable speed control
Model
DA89X1C-23FZ
Fan motor output
(W)
20
Air flow rate
(Cooling / Heating)
(m
3
/ min)
27/27
Piping
Type
Flare connection
connection
Indoor unit
Liquid side
(mm)
∅
6.35
Gas side
(mm)
∅
9.52
Outdoor unit
Liquid side
(mm)
∅
6.35
Gas side
(mm)
∅
9.52
Maximum length
(m)
10
Maximun charge-less length (m) 10
Maximum height difference (m) 8
Refrigera
nt Name of refrigerant R410A
Weight
(kg)
0.63
Wiring
Power supply
3 Wires: Includes earth (Outdoor)
connection
Interconnection
4 Wires: Includes earth
Usable temperature range
Indoor
(Cooling / Heating)
(
o
C)
21 - 32/Up to 27
Outdoor
(Cooling / Heating)
(
o
C)
15 - 43/-10 - 24
Access
ory Indoor unit Installation plate 1
Wireless remote controller
1
batteries
2
Remote controller holder 1
Super Oxi Deo filter
1
Super Sterilizer filter
1
Mounting screw 6 (
∅
4 x 25L)
Plasma air purifier
-
Installation manual 1
Owner's manual
1
Outdoor unit
Drain nipple
1
Water proof rubber cap
-
* The specification may be subject to change without notice for purpose of improvement.
FILE NO. SVM-07008
Pan head wood screw 2 (
∅
3.1 x 16L)
Summary of Contents for RAS-10N3ACV Series
Page 16: ...FILE NO SVM 07008 15 4 2 Outdoor Unit C L C L ...
Page 17: ... 16 FILE NO SVM 07008 5 WIRING DIAGRAM 5 1 Indoor Unit ...
Page 18: ...FILE NO SVM 07008 17 5 2 Outdoor Unit ...
Page 83: ...FILE NO SVM 07008 82 P C board layout Solder side ...