Insulate the refrigerant pipes separately
with insulation, not together.
2
3
8
6
4
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose sloped
downward.
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
6 mm thick heat resisting
polyethylene foam
1
Batteries
Flat head
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Wireless remote control
Saddle
Extension
drain hose
(Not available,
provided by installer)
Shield pipe
Filter
(Attach to the front panel.)
Air
fi
lter
Hook
Installation
plate
Hook
65 mm or more
170 mm or more
170 mm or more
600 mm or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
5
Filter
8
Flat head
wood screw
&
(
Flat head
wood screw
Battery cover
Before installing the wireless remote controller
•
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (- ) positions.
3 Batteries
2 Wireless remote controller
10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
The provided Remote Controller is a
wireless type, which also can be used
as a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.
Remark :
•
Detail of accessory and installation
parts can see in the accessory sheet.
•
Some pictures might be different from
the actual parts.
FILE NO. SVM-12057
–