PRECAUTIONS FOR SAFETY

PRECAUTIONS FOR SAFETY

New refrigerant air conditioner installation

To disconnect the appliance from the main power supply

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems 
or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.

CAUTION

WARNING

DANGER

CAUTION

CAUTION

•  Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
•  Do not install in a place which cannot bear the weight of the unit.
  Personal injury and property damage can result if the unit falls.
•  Before doing the electrical work, attach an approved plug to the power supply cord.
  Also, make sure the equipment is properly earthed.
•  Appliance shall be installed in accordance with national wiring regulations.
  If you detect any damage, do not install the unit. Contact your TOSHIBA dealer immediately.
•  Do not use any refrigerant different from the one speci

fi

 ed for complement or replacement.

  Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to 

your body.

• 

THIS AIR CONDITIONER USES THE NEW HFC REFRIGERANT (R410A), WHICH DOES NOT DESTROY THE OZONE LAYER.

 

R410A refrigerant is apt to be affected by impurities such as water, oxidizing membranes, and oils because the pressure of R410A refrigerant is approx. 
1.6 times of refrigerant R22. As well as the adoption of this new refrigerant, refrigerating machine oil has also been changed. Therefore, during installation 
work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter the refrigeration cycle of a new-refrigerant air conditioner.

  To avoid mixing refrigerant and refrigerating machine oil, the sizes of charging port connecting sections on the main unit are different from those for the 

conventional refrigerant, and different size tools are also required. For connecting pipes, use new and clean piping materials with highpressure withstand 
capabilities, designed for R410A only, and ensure that water or dust does not enter. Moreover, do not use any existing piping as its pressure withstand 
may be insuf

fi

 cient and may contain impurities.

•  FOR USE BY QUALIFIED PERSONS ONLY.
•  TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF.
  FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
•  CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE 

DAMAGED.

•  CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
•  DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
  FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
•  TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT 

SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.

•  WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED 

REFRIGERANT (R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE 
REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF 
THE PIPE AND INJURIES ON PERSONS.

•  IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO 

THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.

•  Exposure of unit to water or other moisture before installation could result in electric shock.
  Do not store it in a wet basement or expose to rain or water.
•  After unpacking the unit, examine it carefully for possible damage.
•  Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and 

discharged air might disturb neighbors.

•  To avoid personal injury, be careful when handling parts with sharp edges.
•  Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
•  The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.

For general public use

Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed 

fl

 exible cord (design H07RN-F) or cord designation 

60245 IEC66 (1.5 mm

2

 or more). (Shall be installed in accordance with national wiring regulations.)

This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles. 

The installation circuit breaker must be used speci

fi

 ed for the power supply line of this air conditioner.

Book 1110251262-1.indb   1

Book 1110251262-1.indb   1

7/13/12   8:59 AM

7/13/12   8:59 AM

Summary of Contents for RAS-10N3KVR Series

Page 1: ...eries Outdoor unit RAS 10 13 16N3AV R Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL ENGLISH ESPAÑOL FRANÇAIS PORTUGUÊS PУCСКИЙ TÜRKÇE 1110251262 1 Book 1110251262 1 indb 1 Book 1110251262 1 indb 1 7 3 12 9 20 AM 7 3 12 9 20 AM ...

Page 2: ... de la Remise en Marche Automatique 8 PRECAUÇÕES RELATIVAS A SEGURANÇA 1 ESQUEMA DE INSTALAÇÃO DAS UNIDADES INTERIOR E EXTERIOR 2 Peças de Instalação Opcionais 2 UNIDADE INTERIOR 3 Local de Instalação 3 Cortar um Orifício e Montar a Placa de Instalação 3 Ligações Eléctricas 3 Como ligar o controlo remoto para funcionamento com cabo 4 Instalação da Tubagem e do Tubo Flexível de Dreno 5 Colocação da...

Page 3: ... BY QUALIFIED PERSONS ONLY TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK MAKE SURE ALL POWER SWITCHES ARE OFF FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK CONNECT THE CONNECTING CABLE CORRECTLY IF THE CONNECTING CABLE IS CONNECTED WRONGLY ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS O...

Page 4: ...ping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Flat head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddle Extension drain hose Not avail...

Page 5: ...nit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION CAUTION Failur...

Page 6: ... shown on figure 8 5 Fix control wire which arrange as shown on figure 9 and to terminal by provided screws tighten firmly but not over 0 25 N m 0 03 kgf m 6 Set control wire through gutter way at rear side of remote controller as shown on figure 7 Fix provided screw Ø3 1 16L on the wall to hang remote controller as shown on figure 8 Mark and arrange hole for fix below screw Ø3 1 25L as shown on f...

Page 7: ...with original screw How to fix the drain cap 1 Insert hexagon wrench 4 mm in a center head 2 Firmly insert the drain cap Firmly insert the drain hose and drain cap otherwise water may leak In case of right or left piping After scribing slits of the front panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool In case of bottom right or bottom left piping After ...

Page 8: ... a passage When the outdoor unit is to be installed in an elevated position be sure to secure its feet The allowable pipe length is up to 20 m If the length is over 15 m add 20 g of refrigerant for every additional meter of the pipe length for all models The allowable height of outdoor unit installation site is up to 10 m A place where the drain water does not raise any problems CAUTION 1 Install ...

Page 9: ...hat the compound pressure gauge reading is 101 kPa 76 cmHg 5 Close the low pressure side valve handle of the gauge manifold valve 6 Open fully the valve stem of the packed valves both gas and liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Using a vacuum pump Packed valve at liquid side Service port Valve core Setting pin Packed valve ...

Page 10: ... B is memorized Picture 2 Remote Control A B Selection When two indoor units are installed in the same room or adjacent two rooms if operating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not re...

Page 11: ...H HE УCTAHABЛИBAЙTE УCTPOЙCTBO B MECTAХ CКOПЛEHИЯ BOCПЛAMEHЯЮЩИХCЯ ГAЗOB ИЛИ ПAPOB HECOБЛЮДEHИE ЭTOГO TPEБOBAHИЯ MOЖET ПPИBECTИ К ПOЖAPУ ИЛИ BЗPЫBУ ДЛЯ ПPEДOTBPAЩEHИЯ ПEPEГPEBA BHУTPEHHEГO БЛOКA И BOЗHИКHOBEHИЯ OПACHOCTИ ПOЖAPA PAЗMECTИTE УCTPOЙCTBO BДAЛИ HA PACCTOЯHИИ БOЛEE 2 M OT ИCTOЧHИКOB TEПЛA HAПPИMEP PAДИATOPOB OБOГPEBATEЛEЙ ПEЧEЙ ПЛИT И T П ПPИ ПEPEMEЩEHИИ КOHДИЦИOHEPA BOЗДУХA ДЛЯ EГO УCTA...

Page 12: ...дpeнaжнaя тpyбкa Oтcyтcтвyeт пpeдоcтaвляeтcя оpгaнизaциeй ycтaнaвливaющeй кондиционep Зaщитнaя оболочкa фильтp Пpикpeпить к пepeднeй пaнeли Bоздyшный фильтp Кpюк Уcтaновочнaя плacтинa Кpюк 65 мм или болee 170 мм или болee 170 мм или болee 600 мм или болee 100 мм или болee 100 мм или болee 600 мм или болee 600 мм или болee Замечание Лодробный перечень принадлежностей и установочных деталей приведен...

Page 13: ... м a Пyльт диcтaнционного yпpaвлeния ДУ Пyльт диcтaнционного yпpaвлeния ДУ Дaльноcть пpиeмa Bнyтpeнний блок ПPEДOCTEPEЖEHИE Пpи кpeплeнии блокa нa бeтонной киpпичной или подобной cтeнe отвepcтия в нeй должны имeть диaмeтp 5 мм Bcтaвьтe подxодящиe втyлки для кpeпeжныx винтов 7 ПPИMEЧAHИE Зaкpeпитe чeтыpe yглa и нижниe чacти ycтaновочной плacтины 4 6 кpeпeжными винтaми ПPEДOCTEPEЖEHИE He допycкaйтe ...

Page 14: ...ра как показано на рисунке 7 4 Вставьте контрольный провод с задней стороны ПДУ как показано на рисунке 8 5 Закрепите контрольный провод проложив его как показано на рисунках 9 и к клемме прилагаемыми винтами затяните надежно но не превышая момент затяжки 0 25 Н м 0 03 кгс м 6 Вставьте контрольный провод в канавку с задней стороны ПДУ как показано на рисунке 7 Закрепите прилагаемые винты Ø3 1 16L ...

Page 15: ... тpyбки поcлe ycтaновки блокa pиcyнок Кaк ycтaновить peшeткy вxодa воздyxa нa внyтpeнний блок Пpикpeплeниe peшeтки вxодa воздyxa выполняeтcя в поpядкe обpaтном поpядкy cнятия ПPEДOCTEPEЖEHИE Уcтaновкa Tpyбопpоводов и Дpeнaжной Tpyбки Cзaди cпpaвa Cзaди cлeвa Bнизy cлeвa Cлeвa Bнизy cпpaвa Cпpaвa Bыpeзaниe отвepcтия в пepeднeй пaнeли Зaмeнa дpeнaжной тpyбки Подготовкa тpyбопpоводa Oтвepcтиe Oтвepcт...

Page 16: ... хладагента на каждый дополнительный метр длины трубы для всех моделей Допустимая высота места для установки наружного блока может составлять не более 10 метров Mecто гдe вытeкaющaя водa нe cоздaeт пpоблeм ПPEДOCTEPEЖEHИE 1 Уcтaновитe нapyжный блок тaк чтобы ничто нe блокиpовaло выxод воздyxa 2 Ecли нapyжный блок ycтaнaвливaeтcя в мecтe вceгдa подвepжeнномy воздeйcтвию cильного вeтpa нaпpимep нa п...

Page 17: ...pонe гaзового тpyбопpоводa 2 Подcоeдинитe зaгpyзочный шлaнг к поpтy вaкyyмного нacоca 3 Oтвepнитe полноcтью pyчкy мaномeтpичecкого коллeктоpa нa cтоpонe низкого дaвлeния 4 Bключитe вaкyyмный нacоc чтобы нaчaть откaчкy воздyxa Bыполняйтe откaчкy воздyxa в тeчeниe пpимepно 15 минyт ecли длинa тpyбки paвнa 25 мeтpaм 15 минyт пpи 25 мeтpax ecли пpоизводитeльноcть нacоca paвнa 27 литpaм в минyтy Зaтeм ...

Page 18: ...T на внутреннем блоке в течение 3 секунд чтобы отменить режим работы устройство издаст 3 звуковых сигнала а индикатор OPERATION не будет мигать Если установлен таймер включения или выключения ФУНКЦИЯ АВТОМАТИЧЕСКОГО ВОЗОБНОВЛЕНИЯ РАБОТЫ не будет активизирована Oголeниe концa cоeдинитeльного кaбeля Cоeдинитeльный кaбeль Шнyp питaния Жилa зaзeмлeния Жилa зaзeмлeния Cоeдинитeльный кaбeль Блок paзъeмо...

Reviews: