– 3 –
FILE NO. SVM-03001
MODEL
RAS-13UKHP-ES2, AS2
RAS-13UKP-ES2, AS2
RAS-13UAH-ES2, AS2
RAS-13UA-ES2, AS2
ITEM
Cooling
Heating
Cooling
Capacity
220V
240V
220V
240V
220V
240V
kW
3.60
3.60
4.20
4.26
3.75
3.75
Phase
1
∅
Power source
V
220 – 240
Hz
50
Power consumption
kW
1.10
1.12
1.14
1.18
1.13
1.17
Power factor
%
98
97
97
96
98
97
Running
Indoor
A
0.15
current
Outdoor
A
4.95
4.65
5.20
4.95
5.10
4.90
Starting current
A
27
28
Moisture removal
lit/h
2.0
Noise
Indoor (H/M/L)
dB
41/35/31
Outdoor (220-240V)
dB
49
51
49
51
49
50
Refrigerant
Name of refrigerant
R410A
Rated amount
kg
1.00
0.97
Refrigerant control
Capillary tube
Gas side size
mm
∅
12.7
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
15*
1
(One way)
Maximum height
m
6
difference
INDOOR UNIT
RAS-13UKHP-ES2, AS2
RAS-13UKP-ES2, AS2
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
630
650
630
Air volume
Medium fan
m
3
/h
520
550
520
Low fan
m
3
/h
430
490
430
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-13UAH-ES2, AS2
RAS-13UA-ES2, AS2
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight
kg
40
37
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
2120
2200
2120
2200
2120
2200
Fan motor output
W
42
Compressor
Model
PA150X2T-4FM1
Output
W
1100
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°C
15 ~ 43
–10 ~ 24
15 ~ 43
1. SPECIFICATIONS