– 68 –
No.
Part name
Inverter
assembly
Procedure
1. Detachment
1) Perform work of item 1 of
.
2) Remove screw (ST1TØ4 x 10 2 pcs.) of the
upper part of the front cabinet.
• If removing the inverter cover in this condition,
P.C. board can be checked.
• If there is no space in the upper part of the upper
cabinet, perform work of
.
Be careful to check the inverter because
high-voltage circuit is incorporated in it.
3) Perform discharging by conn , – polarity by
discharging resistance (approx. 100
Ω
40W) or plug
of soldering iron to + , – terminals of the C14
(printed “CAUTION HIGH VOLTAGE” is attached.)
electrolytic capacitor (500µF) on P.C. board.
Be careful to discharge the capacitor
because the electrolytic capacitor cannot
naturally discharge and voltage remains
according to trouble type in some cases.
NOTE :
This capacitor is one with mass capacity.
Therefore, it is dangerous that a large spark
generates if short-circuiting b , –
polarity with screwdriver, etc. for discharging.
4) Remove screw (ST1TØ4 x 10 2 pcs.) fixing the
main body and the inverter box.
5) Remove various lead wires from the holder at
upper part of the inverter box and wiring holder at
right side of the terminal block.
6) Remove the lead wire from the bundled part at left
side of the terminal block.
7) Pull the inverter box upward.
8) Disconnect connectors of various lead wires.
Requirement :
As each connector has a lock mechanism,
avoid to remove the connector by holding
the lead wire, but by holding the connector.
Remarks
The connector is one with lock,
so remove it while
pushing the part
indicated by an
arrow.
Be sure to remove the connector
by holding the connector, not by
pulling the lead wire.
Terminal block
Inverter cover
P. C. board
(Soldered surface)
Discharging position
(Discharging period
10 seconds or more)
Plug of
soldering
iron
Bundled
part
Holder