Heat insulator

Drain hose

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

How to remove the drain cap

Clip the drain cap by needle-nose 

pliers and pull out.

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 

the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

firmly until the connection part contacts with heat 

insulator, and then secure it with original screw.

How to fix the drain cap

1)  Insert hexagon wrench (4 mm) 

  in a center head.
2)  Firmly insert the drain cap.

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  Take off the cap by hand and cut of the slit.

•  After scribing slits of the bush body with a knife or a making-off pin, cut 

them with a pair of nippers or an equivalent tool. 

In case of bottom right or bottom left piping

•  After scribing slits of the bush body with a 

knife or a making-off pin, cut them with a 

pair of nippers or an equivalent tool. 

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 43 mm above the wall  

surface.  If  the  connecting  pipe  is  laid  exceeding  43  mm  above  the  wall  

surface, the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so as 

not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (figure)

CAUTION

Do not apply lubricating oil

(refrigerant machine oil)

when inserting the drain

cap. Application causes

deterioration and drain

leakage of the plug.

No gap

Insert a hexagon wrench

(4 mm).

 

 

326 mm

283 mm

43 mm

80°

Liquid side

Gas side

(To the forefront of flare)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)

core or the like for bending pipe.)

Use the handle of screwdriver, etc.

Slit

Cap

Slit

 

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.

After passing the connecting pipe through the pipe hole, connect the 

connecting pipes to the auxiliary pipes and wrap the facing tape around 

them.

•   Do not perform flare connection inside a building or dwelling or room, 

when  joining  the  heat  exchanger  of  indoor  unit  with  interconnection 

piping.  Refrigerant  connection  inside  a  building  or  dwelling  or  room 

must be made by brazing or welding. Joint connection of indoor unit by 

flaring method can only be made at outdoor or at outside of building or 

dwelling or room. Flare connection may cause gas leak and flammable 

atmosphere.

WARNING

1. Die-cutting bush body slit

  •  For Bottom left or Bottom right

    Cut out the slit on bottom left or right side of bush body for the bottom left 

or right connection with a pair of nippers.

  •  For Left or Right 

Take off Cap and cut out the slit on left or right side of bush body for the 

left or right connection with a pair of nippers.

2. Changing drain hose

  For leftward connection, bottom-leftward connection and rearleftward 

connection’s piping, it is necessary to change the drain hose and drain 

cap.

Rear right

Rear left

Bottom left

Left

Bottom right

Right

Die-cutting bush body 

slit

Take of

f cap 

and cut bush 

body slit

Changing drain hose

Piping preparation

Changing

drain 

 

hose

•  Bind the auxiliary pipes (two) and connecting cable with facing tape 

tightly.  In  case  of  leftward  piping  and  rear-leftward  piping,  bind  the 

auxiliary pipes (two) only with facing tape.

 

Indoor unit

Connecting cable

Auxiliary pipes

Installation plate

•  Carefully arrange pipes so that any pipe does not stick out of the rear 

plate of the indoor unit.

•  Carefully  connect  the  auxiliary  pipes  and  connecting  pipes  to  one  

another and cut off the insulating tape wound on the connecting pipe 

to  avoid  double-taping  at  the  joint;  moreover,  seal  the  joint  with  the 

vinyl tape, etc.

•  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

•  When bending a pipe, carefully do it, not to crush it. 

CAUTION

01_1121451198-EN.indd   8

4/26/2561 BE   10:06 AM

Summary of Contents for RAS-16PKVPG-E

Page 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL Indoor unit RAS 10PKVPG E RAS 13PKVPG E RAS 16PKVPG E Outdoor unit RAS 10PAVPG E RAS 13PAVPG E RAS 16PAVPG E 1121451198 ENGLISH R32 ...

Page 2: ...oor unit is fixed to Installation plate with screws 9 n Drainage 9 OUTDOOR UNIT 10 n Installation Place 10 n Precautions about Installation in Regions with Showfall and Cold Temperatures 10 n Refrigerant Piping Connection 10 n Evacuating 11 ELECTRICAL WORKS 12 n Wiring Connection 12 n Power Supply and Connecting Cable Connection 13 n Power supply input Wiring Diagram 14 OTHERS 15 n Gas Leak Test 1...

Page 3: ... incorrect use of this unit may cause severe injury or death CAUTION It indicates that incorrect use of this unit may cause personal injury 1 or property damage 2 1 Personal injury means a slight accident burn or electrical shock which does not require admission or repeated hospital treatment 2 Property damage means greater damage which affects assets or resources CAUTION This appliance must be co...

Page 4: ...ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNACE ...

Page 5: ...d possibly result in explosion and injury Thickness of copper pipes used R32 must be more than 0 8mm Never use copper pipes thinner than 0 8mm Do not perform flare connection inside a building or dwelling or room when joining the heat exchanger of indoor unit with interconnection piping Refrigerant connection inside a building or dwelling or room must be made by brazing or welding Joint connection...

Page 6: ...ual carefully before installing the unit It contains further important instructions for proper installation The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installat...

Page 7: ...Vacuum or wash and then dry them 4 Reinstall the air filters and close the air inlet grille ACCESSORY AND INSTALLATION PARTS No Parts name No Parts name 1 Installation plate x 1 2 Wireless remote control x 1 3 Battery x 2 4 Remote control holder x 1 5 Mounting screw ø4 x 25 l x 6 6 Flat head wood screw ø3 1 x 16 l x 2 7 Drain nipple x 1 for heating model only 8 Cap water proof x 2 for some models ...

Page 8: ...it and wall and tilt the indoor unit for better operation The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Do not allow the drain hose to get slack Make sure to run the drain hose sloped downward The flare connection should be installed outdoors Insulate the refrigerant pipes separately with insulation not together 6 mm thick heat resisting p...

Page 9: ...ncrete wall with anchor bolts use the anchor bolt holes as illustrated in the below figure 3 Install the installation plate horizontally in the wall When installing the installation plate with a mounting screw do not use the anchor bolt holes Otherwise the unit may fall down and result in personal injury and property damage 1 After determining the pipe hole position on the mounting plate drill the...

Page 10: ...polyethylene core or the like for bending pipe Use the handle of screwdriver etc Slit Cap Slit NOTE If the pipe is bent incorrectly the indoor unit may unstably be set on the wall After passing the connecting pipe through the pipe hole connect the connecting pipes to the auxiliary pipes and wrap the facing tape around them Do not perform flare connection inside a building or dwelling or room when ...

Page 11: ... extension drain hose insulate the connecting part of extension drain hose with shield pipe NOTE The hole should be made at a slight downward slant on the outdoor side Arrange the drain pipe for proper drainage from the unit Improper drainage can result in dew dropping CAUTION This air conditioner has the structure designed to drain water collected from dew which forms on the back of the indoor un...

Page 12: ...ain water does not raise any problems CAUTION Do not scratch the inner surface of the flared part when removing burrs Flare processing under the condition of scratches on the inner surface of flare processing part will cause refrigerant gas leak CAUTION When the outdoor unit is installed in a place where the drain water might cause any problems Seal the water leakage point tightly using a silicone...

Page 13: ...p 3 Open fully the low pressure side handle of the gauge manifold valve 4 Operate the vacuum pump to start evacuating Perform evacuating for about 15 minutes if the piping length is 25 meters 15 minutes for 25 meters assuming a pump capacity of 27 liters per minute Then confirm that the compound pressure gauge reading is 101 kPa 76 cmHg 5 Close the low pressure side valve handle of the gauge manif...

Page 14: ...e 1 2 N m 0 12 kgf m 7 Secure the cable with the cord clamp 8 Fix the terminal cover and attach front panel to the indoor unit 1 Remove the valve cover from the outdoor unit 2 Connect the cable to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor unit 3 When connecting the cable to the outdoor unit terminals make a loop as shown in the in...

Page 15: ...e Stripping length of the connecting cable Stripping length of the connecting cable Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit 100 mm 10 mm 10 mm 90 mm Power supply terminal block L N Connecting terminal block 1 2 3 Earth line Connecting cable cord Power supply cord Earth line Connecting cable about 20 cm Plastic wire guide 45 mm 50 mm 10 mm 10 mm Connecting cable connect to terminal block ...

Page 16: ... may cause some electrical part burn out 8 Incorrect or incomplete wiring is carried out it will cause an ignition or smoke 9 This product can be connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3mm must be incorporated in the fixed wiring Power supply input Wiring Diagram Indoor Terminal Block Power supply input O...

Page 17: ...ame room or adjacent two rooms if operating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation betwe...

Reviews: