7
A
B
OTHERS
Gas Leak Test
•
Check the fl are nut connections, valve stem cap connections and service
port cap connection for gas leak with a leak detection or soap water.
Model
RAS-18BKS
RAS-24BKS
e
s
a
h
p
e
l
g
n
i
S
V
0
4
2
–
0
2
2
,
z
H
0
5
e
c
r
u
o
s
r
e
w
o
P
Maximum running current
12.5A
15.4A
Plug socket & fuse rating
A
0
2
A
6
1
Power cord
4 mm
2
(H07RN-F or 60245 IEC66)
or 3.5 mm
2
(AWG-12)
70
L N
10
60
10
70
10
80
10
1 2 3
L
N
1
3
2
Terminal block
Earth line
Cord clamp
Earth line
Terminal screw
Cord clamp
Screw
Power supply cord
Connecting cable
Power supply cord
Connecting cable
Earth line
Stripping length of the connecting cable
CAUTION
•
Wrong wiring connection may cause some electrical parts burn out.
•
Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
•
Every wire must be connected fi rmly.
•
If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
•
Prepare the power supply for exclusive use with the air conditioner.
•
This product can be connected to the mains.
Connection to fi xed wiring : A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fi xed wiring.
NOTE
: Connecting cable
•
Wire type : More than 1.5 mm
2
(H07RN-F or 60245 IEC66) or 1.3 mm
2
(AWG-16)
Service port cap connection
Valve stem cap connection
Flare nut connections
(Outdoor unit)
Flare nut connections
(Indoor unit)
Valve stem cap connection
Remote Control A-B Selection
•
When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
•
The remote control signal is not received when the settings of indoor unit
and remote control are different.
•
There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display (Picture
1
).
4. Press [MODE] during pushing [CHECK]. “B” will show on the display and
“00” will disappeared and the air conditioner will turn OFF. The Remote
Control B is memorized (Picture
2
).
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not “A” display .
3. Default setting of Remote Control from factory is A.
2
1
Test Operation
Auto Restart Setting
How to set the Auto Restart
1. Press and hold the [RESET] button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
2. Press and hold the [RESET] button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
•
In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
To switch the TEST RUN (COOL) mode, press [RESET] button for 10
seconds. (The beeper will make a short beep.)
RESET button
Information
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
Electrical Work
1. The supply voltage must be the same as the rated voltage of the air
conditioner.
2. Prepare the power source for exclusive use with the air conditioner.
VT
1115551271_(01_EN).indb 7
12/17/15 3:30 PM
Summary of Contents for RAS-18BAS Series
Page 10: ...MEMO 1115551271_ 01_EN indb C3 1115551271_ 01_EN indb C3 12 17 15 3 30 PM 12 17 15 3 30 PM ...
Page 11: ...MEMO 1115551271_ 01_EN indb C4 1115551271_ 01_EN indb C4 12 17 15 3 30 PM 12 17 15 3 30 PM ...
Page 12: ...70 L N 10 60 10 70 10 80 10 1 2 3 L N 1 3 2 A B AWG 16 RESET RESET RESET AWG 12 60245 IEC66 ...
Page 17: ... ﻣﻢ 108 ﻣﻢ 600 ﻣﻢ 28 ﻢ ﻣ 2 5 ﻣﻢ 90 ﻣﻢ 125 ﻣﻢ 320 ﻣﻢ 86 ﻣﻢ 102 Ø 8 10 A B C ...
Page 19: ......
Page 20: ...S e r i e s S e r i e s ...