No.
Part name
Procedures
Remarks
5
Side cabinet
1.
Side cabinet (right)
1)
Perform step 1 in
2
and all the steps in
3
.
2)
Remove the fixing screw (S
T
2
TØ4 × 10L
4
pcs.) used for securing the side cabinet
to
the bottom plate and valve fixing panel
2.
Side cabinet (left)
1)
Perform step 1 in
2
.
2)
3)
Remove the fixing screw (S
T
2
TØ4 × 10L
1 pc.) used to secure the side cabinet (left)
onto the heat exchanger.
Remove the fixing screw (S
T
2
TØ4 × 10L
2 pcs.) used for securing the side cabinet to
the bottom plate and heat exchanger.
6
Fan motor
1)
Perform work of item 1 of
1
and
2
.
2)
Remove the f
l
ange nut f
i
xing the fan motor and
the propeller.
• Flange nut is loosened by turning
clockwise.
(To tighten the flange nut, tur
n
counterclockwise.)
3)
Remove the propeller fan.
4)
Disconnect the connector for fan motor from
the inverter.
5)
Remove the f
i
xing screws (4 pcs.) holding by
hands so that the fan motor does not fall.
* Precautions when assembling the fan motor
Tighten the flange nut using a
tightening
torque of 4.9 N•m.
Detail A
Detail B
Detail C
Hook the claw noto
the bottom plate
The back body section hooked
onto the bottom plate here.
Propeller fan
Fan motor
Flange nut
- 127 -