Item
1
4
. Self-Cleaning
function
Operation flow and applicable data, etc.
1
4
-1-1. Self-Cleaning diagram
Description
Operation display
ON
OFF
OFF
FCU fan
ON
ON
OFF
rpm is depend on presetting.
(500RPM)
FCU louver
OPEN
OPEN (12.7º)
CLOSE
Timer display
ON or OFF
ON
ON or OFF
depend on presetting of timer function.
depend on presetting of timer function.
Compressor
ON or OFF
OFF
OFF
depend on presetting per room temperature.
CDU fan
ON or OFF
OFF
OFF
depend on presetting per room temperature.
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning mode
operate 30 mins.
Automatically turn-off.
Operation time
Turn off by remote controller or
timer-off function.
•
ON
OFF
ON
OFF
•
Turn on air conditioner again by remote controller
to confirm setting.
Note) Table above will show current status of
Self-Cleaning function
Set or Cancel Self-Cleaning function by push
the RESET button on air conditioner.
When setting is changed, the sound warning will
alarm "Beep". The setting is changed following
below.
1
4
-1-2. Self-Cleaning function release
How to set/cancel Self-Cleaning function
To set/cancel the Self-Cleaning function, proceed as
follows:
1
•
Setting diagnosis code "06" on remote controlle
(See detail of setting diagnosis code in 11-4-1)
Turn on the power supply to air conditioner, after
that press [RESET] button on air conditioner 1
time to turn on the air conditioner (The LED
display will show in operation LED)
1
Take the remote controller to direction of LED
display on air conditioner, press button "up" (see
detail of setting diagnosis code in 11-4-1) 1 time
to send the code "07"
*(within 3 sec. after press [RESET] button),* then
air conditioner will shutdown automatically. Also,
LED display will show flash follow the able below.
•
•
OPERATION /
RESET Button
ON
Operation LED
Self-cleaning
F
lash 1 Hz
function
Timer LED
Flash 1 Hz
OFF
F
lash 1 Hz
None
- 51 -