Item
Operation flow and applicable data,etc
Description
19
.
QUIET mode
Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.
Remarks :
1.
2.
Quiet mode is unable to work in dry mode.
Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Because of the fan speed L- may cause not
enough the cooling capacity or heating
capacity.
2
0
. Display lamp
brightness
adjustment
To decrease the display lamp brightness or turn it off.
1. Press and hold
FAN
for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press
Rise
or
Decrease
to adjust brightness in 4 levels.
● In the examples of and , the lamp illuminates for 5 seconds before
going off.
When the "Quiet mode" selected from [
QUIET
] button;
-
The fan of the indoor unit will be restricted the
revolving speed at speed UL.
-
The compressor speed is controlled as shown
in the figure.
The '' Quiet mode '' is canceled by [
QUIET
]
button is pressed to select other speed.
Remote control
LCD
Operation display
Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the
operation lamp is turned off.
50%
All lamps are turned off.
All turned off
Model
05
Ŭ
07
Ŭ
10
Ŭ
Cool min (Hz)
20
20
20
Quiet Cool (Hz)
31
31
35
Heat min (Hz)
20
20
20
Quiet Heat (Hz)
31
31
31
Model
13
Ŭ
16
Ŭ
18
Ŭ
Cool min (Hz)
20
20
20
Quiet Cool (Hz)
35
35
35
Heat min (Hz)
20
20
20
Quiet Heat (Hz)
31
55
3
8